Kemppi fastmig MF 29 Operation Instructions Manual - 2.10. Main Switch I/o
2.10. MAIN SWITCH I/O
When you turn the main switch of the FastMig™ power source into I-position, the pilot lamp
closest to this switch will light up, indicating the power source is ready for welding.
Always start and switch off the machine with the main switch, never use the mains
plug as a switch.
2.11. OPERATION OF COOLING UNIT, FASTCOOL 10
Operation of cooling unit is controlled in such a way that pump is started when welding is started.
After welding stop pump is rotating for approx. 5 min cooling the gun and the cooling liquid to
ambient temperature.
Read in operation instructions for the Fastcool 10 unit the trouble situations of the liquid circulation
system and protection against torch etc. damage.
2.12. HANGING
MF 29 can be hanged to the barrier with an optional hanging frame (6185285). The machine is not
supposed to be hanged from its handle.
3. SERVICE, OPERATION DISTURBANCES
The amount of use and the working environment should be taken into consideration when planning
the frequency of maintenance of MF. Careful use and preventive maintenance will help to ensure
trouble-free operation.
The following maintenance operations should be carried out at
least every six months:
Check:
– The wear of the grooves of the feed rolls. Excessive wear
of grooves causes problems in wire feed.
– The wear of the wire guide tubes of wire feed. Badly worn
feed rolls and wire guide tubes should be discarded.
– The wire guide tube in the gun should be set as near the
feed rolls as possible, but not touching them and the wire
must follow a straight line from the end of the tube to the
groove of the feed roll.
– Reel brake adjustment.
– Electric connections
* Oxidised couplings must be cleaned
* Loose couplings must be tightened
Clean dust and dirt from the equipment.
When using compressed air, always protect your eyes with proper eye protection.
In case of problems contact your KEMPPI dealer.
twice
a year
FASTMIG™ MF 29 / 0603 – 11
© KEMPPI OY