Default Factory Setting:
LOAD GROUP 1
MODE = 1 ON with Ignition, OFF with Ignition
LOAD GROUP 2
MODE = 2 ON with Ignition, OFF with Timer
TIMER = 2 minutes
LOAD GROUP 3
MODE = 3 ON with Battery, OFF with Programmed Voltage Disconnect
LVD SET = 11.5 volts (Reconnect 13.0V)
VI) OPERATION
A) Fuse Installation: We recommend pre-installing fuse values before powering PDS-100. The PDS-100 will accept ATO/
ATC style fuses, 20 Amp maximum rating.
B) Fuse Removal: Firmly grip fuse with fingers or needle nose pliers and pull straight out
C) Fuse OK LED: A green LED next to each fuse will illuminate when a good fuse is installed
Note: If using blown fuse indicating type fuses a minimum load of at least 20 milliamps is required for proper indication
D) Master Under Voltage Shutdown (UVS) & Over Voltage Shutdown (OVS)
UVS - If the INPUT bus voltage drops below 10.5V for more than 20 seconds all Load Group relays will de-energize
and all loads will disconnect from the INPUT bus and will reconnect when battery voltage is restored to 13V.
OVS – If the INPUT bus increases to over 16V all Load Groups relays will de-energize and loads will disconnected
from the INPUT bus and will restore 15V.
E) Input Power and Power Mode Indicators
INPUT POWER LED – indicates the presence of voltage on INPUT bus (>6 volts)
POWER MODE LED – rate of flashing light indicates different power conditions:
OVS: Over Voltage Shutdown, all circuits off – constant flashing at a rate of once every 1 second.
UVS: Low Voltage Shutdown, all circuits off – constant flashing at a rate of once every 2 seconds.
IGN: Ignition not present – quickly flashes 3 times every 2 seconds.
VII) Specifications
Electrical:
Input: 12V, neg. ground
Power Consumption: Idle: 8mA, Active: 180 mA/circuit
Maximum Load: 100A per PDS, 20A max. per fuse position
Maximum System: 3 PDS wired in parallel, 18 circuits
Fuse Type: ATC/ATO
Programmable Timer Range: 2 min. – 13 hours
Low Voltage Disconnect Point Range: Selectable per load group, 10.3 to 11.8V (see table 6 for reconnect voltages), 20
second delay
Master Disconnect: High Voltage 16.0V (OVS), Low Voltage 10.5 (UVS), 20 second delay
Operating Temperature Range: -20˚ C to +60˚ C
Mechanical:
Case: Powder coated aluminum
Protective Covers: Battery “+” bus and “+” power out terminals
Dimensions (H x W x D): 5.6” x 4.75” x 3.1”, Weight: 2 Lbs.