The modes are as follows:
1) ON with Ignition, OFF with Ignition: Circuits will be energized anytime the ignition signal is ≥5 volts and de-energized if
2) ON with Ignition, OFF with Timer: Relay will stay energized after the ignition signal reaches
set by dip-switches labeled 1 through 4 of that relay group.
3) ON with Battery Power, OFF by Load Group LVD: Relay will stay energized until the battery voltage drops below a
specified level for 20 seconds set by dip-switches 1 through 4 of that relay group. The ignition signal has no affect
on this group mode.
4) Always ON: Relay energized no matter state of ignition signal, OFF only by Master Under Voltage Shutdown (UVS).
NOTE: Under Voltage Shutdown (UVS) or Over Voltage Shutdown (OVS) will de-energize all relays in any MODE. If the
UVS or OVS threshold is reached before timer times out, power will be disconnected from load group.
Table 4: Power Activation Selection Table
Mode
Description
Switch Position
Switch 6
Switch 5
1
IGN ON/OFF
Down
Down
2
IGN with Timeout
Down
Up
3
LVD
Up
Down
4
Always ON
Up
Up
Timer Duration Selection (MODE 2)
When the Load Group mode is set for mode 2, dip-switch positions 1 though 4 will set the desired timeout duration, which
is the time from when the vehicle IGN is shut off to when the load is disconnected, see Table 5 for timer selection. Timer is
reset when IGN input voltage is again sensed when ignition switch is turned on.
Table 5: Timer Duration Selections
Duration Switch 4 Switch 3 Switch 2 Switch 1
2 min
Down
Down
Down
Down
10 min
Down
Down
Down
Up
30 min
Down
Down
Up
Down
1 hr
Down
Down
Up
Up
2 hrs
Down
Up
Down
Down
3 hrs
Down
Up
Down
Up
4 hrs
Down
Up
Up
Down
5 hrs
Down
Up
Up
Up
6 hrs
Up
Down
Down
Down
7 hrs
Up
Down
Down
Up
8 hrs
Up
Down
Up
Down
9 hrs
Up
Down
Up
Up
10 hrs
Up
Up
Down
Down
11 hrs
Up
Up
Down
Up
12 hrs
Up
Up
Up
Down
13 hrs
Up
Up
Up
Up