AC Power requirements
Caution
Voltage requirements
Caution
Cooling
The KPAK2600 uses a standard PowerCon connector. The device must be connected to a suitable mains
socket outlet with protective earthing connection.
The PowerCon is a connector without breaking capacity, i.e. the PowerCon should not be connected
or disconnected under load or while it is alive. Always isolate your AC supply before disconnecting the
PowerCon connector.
Your KPAK2600 will be supplied pre set to the voltage used in your area. The table below provides typical
current draw figures for the KPAK2600.
If the On LED does not illuminate or the system does not respond to audio input remove AC power
immediately. Verify that the voltage is within the proper range. If the problem persists, please contact
KV2 Audio or an authorized service center.
The KPAK2600 has a comprehensive passive cooling system with demand-sensitive forced cooling back-
up, via speed controlled fans.
This means that the cooling system never drives air across PCB boards, connectors or components,
ensuring prolonged electronic component lifespan and minimizing maintenance cycles.
It is important to have an adequate air supply around the amplifier allow the cooling air to flow. Do not
expose the amplifier heat sink to direct sunlight.
If the heat sink gets too hot, its sensing circuit will open the output relay, disconnecting the load.