The 3000, 3715 and 4715 Entry Devices are designed with keyhole slots
for ease of mounting and battery replacement.
1. Install the two #8-32 shoulder screws (US) or the M4-0.7 shoulder
screws (metric) to mount the Entry Device to the door.
2. Feed the key pad cable through the spindle cable hole from the front
of the safe door. Leave approximately 2 inches (50mm) of the cable
extended out the front of the container door, to allow for
battery replacement.
3. Position the Entry Device over the mounting screws and then side
the
Entry Device down onto the mounting screws. (Figures 1 & 2)
4. Ensure that the Entry Device cable is running through the channel at
the back of the lock.
INSTALLING BATTERIES
1. Slide the keypad housing up and carefully pull away from mounting surface to expose battery compartment.
CAUTION! Hold onto the battery connector to avoid pulling the wires out of the board.
2. Connect a new 9-Volt alkaline battery to the battery connector.
3. Push the battery and the leads completely into the battery compartment.
4. Repeat procedure for second battery ( 3000 only).
5. Carefully position the keypad over the mounting screws
and slide the keypad housing down. Ensure there are no wires
or cables trapped between the Entry Device and the safe door.
Keyhole Slots
Figure 1
Figure 2
9 Volt Battery
Keyhole Slots
3000
3000
3715/4715
3715/4715
3000, 3715 AND 4715 ROUND ENTRY DEVICES