La Pavoni PB-16 Instructions For Use Manual - Maintenance
Your espresso machine is equipped with a manual reset fuse. Should the water
level in the sight glass drop below a 1/5 of a tank or if the machine is left on
indefinitely, these occurrences may cause the machine to over-heat. If the on/off
switch does not light up the fuse may have blown, follow the below steps to restart
your machine.
1. Unplug the unit
2. Close the boiler knob tightly so water does not escape
3. Gently place the machine on its side.
Under the base of the unit you will notice a round grommet plug
inserted into the bottom, directly under the boiler tank. Remove the
plug and push in the protruding red switch by using a blunt
instrument (the end on a pencil of pen works well) replace the
grommet, add water if necessary, plug-in and restart
.
7
MAINTENANCE
•
Before any cleaning and maintenance, disconnect the power cord.
•
Clean the filter handle (10), coffee filters (15), coffee press (13), measuring spoon (14) and
drip basin (6) after use.
•
Wipe clean the group (11) and steam tube (12) after use.
•
If you live in a hard water area and get mineral build up, follow the instructions for
"
FIRST TIME OPERATION."
•
Do not use any types of abrasives or ammonia based products when cleaning your la
Pavoni machine. Clean all models with a damp cloth immediately after the machine has
cooled.
IMPORTANT !!!
SAVE YOUR ORIGINAL LA PAVONI BOX IN CASE SERVICE IS NEEDED IN THE FUTURE.
CAUTION !!!
NEVER OPERATE THIS MACHINE WITHOUT WATER IN THE BOILER