Lagoon 440 User Manual - page 57
A battery monitor (DC meter on the electrical panel) enables control
of the charge, voltage and depletion rate of the service batteries and
of the generator (optional extra).
For its use see the instruction guide.
Always check the battery and charge system condition before you put
out to sea.
Keep the batteries clean and dry in order to avoid premature wear.
Have the acidity level of the battery checked if left unused for a
prolonged period. Check the level regularly.
Tighten and maintain the terminal connectors by lubricating them
regularly with Vaseline.
Batteries and circuit breakers
The electricity onboard is 12 V DC.
The electrical system consists of service batteries. The batteries
supply power to all the functions on board (see SPECIFICATIONS
chapter for battery capacity).
The general 12 V system is turned on by switching to ON the battery
switches located in the port and starboard aft cabins.
z
MAINTENANCE
Keep the batteries charged (essential to ensure longevity).
It is possible to operate with the battery store charged to 80% on the
condition that the batteries are charged weekly to 100%.
Never run batteries down below 70% of their nominal capacity.
Use the battery charger when in a marina to ensure you begin each
trip with properly charged batteries.
ELECTRICITY
55
ELECTRICITY
6
LAGOON 44O
WARNING
A damaged battery will never recover its original
capacity.
The service batteries should be charged to their
maximum.