Lagoon 450 User Manual - page 105
Motonautisme
Motonautisme ou voile
z
Motonautisme ou voile
Motonautisme
Motonautisme ou voile
z
Motonautisme ou voile
LAGOON 450
103
SAFETY
SAFETY
11.2 Gas system
The port side front cockpit locker has been designed to store two gas
cartridges.
The circuits opening / closing valves are located in the cupboard un-
der the oven unit.
The boat in her U.S. version has an electrovalve located in the locker
where the bottles are stored.
Turn on the electronically controlled valve using the related circuit
breaker on the electrical panel.
z
SAFETY INSTRUCTIONS
A gas-powered appliance uses the oxygen and releases combustion
products. Ventilate your boat when you use this appliance.
Regularly check and replace the rubber tubings that link the bottle to
one end of the circuit and the stove to the other one, depending on the
standards and regulations in force in your country.
Close the valves before you change bottles and immediately in case
of emergency.
In case you smell gas or find that the burners have gone out, turn off
the valve of the appliance. Do ventilate the boat in order to get rid of
any residual gas. Find the cause of the problem.
Use only the compartment the gas bottles are alloted to store them
11.3 Fire
The boat is delivered with no extinguisher.
Be sure:
- To fit the boat with extinguishers in pursuance of the regulations of
the country where your boat is registered.
- To have the extinguishers checked in accordance with the instructions
given.
- To refill or replace the extinguishers by similar equipment if the ex-
tinguishers have been used or are out of date.
- Make sure the extinguishers are accessible when people are on
board.
Tell the crew:
- where the extinguishers are and how they work.
- where the extinguisher hole in the engine bay is (under the aft cabins
berths, both on the port and starboard sides).
- where the emergency exits are.
RECOMMENDATION
Close the gas valve and turn off the regulator tap
when the stove and oven are not used.