LAGOON 450
75
7
ELECTRICITY
ELECTRICITY
z
CHECKING OF THE 110 V - 220 V CONSUMING APPLIANCES
SELECTION PANEL (in the cupboard at the saloon starboard entrance):
The panel is composed of selectors allowing to choose the electrical
power source for the different 110 V - 220 V consuming appliances
on board.
LEFT-HAND SIDE SELECTOR:
- allows to use the air conditioning powered by a 110 V - 220 V current
coming from the generator or from the shore power.
RIGHT-HAND SIDE SELECTOR:
- allows to use the appliances requiring a 110 V - 220 V current co-
ming from the generator, the shore power or the inverter.
z
USE OF THE 230 V POWERED APPLIANCES
SWITCHING ON THE APPLIANCES
In order to be able to use the 110 V - 220 V powered appliances
(washing machine, watermaker, etc), it is advisable:
Make sure that the outlet automatic breaker is switched OFF on the
110 V - 220 V selection panel.
- Switch on the 110 V - 220 V source (start the generator or connect a
shore power socket to shore). Select this source on the selection panel
so that this source supplies the boat (110 V - 220 V electrical selection
panel) or turn on the inverter for the outlets.
- Push the automatic breakers of the outlets to be used on the electrical
panel.
Then start the appliance with its own controls.
To start 110 V - 220 V elements, wait for 10 to 15 seconds between
the start up of each new component (in order to allow the generator
to become stabilized and be able to give the power necessary for the
starting up).
STOPPING THE 110 V - 220 V POWERED APPLIANCES
To stop the 110 V - 220 V powered appliances (washing machine, etc.)
it is advisable to do as follows:
- Stop the appliance with its own controls.
To stop 110 V - 220 V elements, wait for 10 to 15 seconds between
the stop of each new component (in order to allow the generator to
become stabilized).
- Turn OFF the automatic breakers of the outlets on the electrical panel.
- Turn to OFF the 110 V - 220 V source selector (generator or shore
power) or turn off the inverter.
- Stop the generator or disconnect the shore power socket.
RECOMMENDATION
Keep an eye on the charge of the batteries when you
use the inverter.
WARNING
Before you turn the 110 V - 220 V source selector
to OFF, make sure no other appliance is working
(danger of an electric arc that would destroy
the changeover switch and risk of damaging the
generator).