Lance-Larkin BREW EXPRESS BE-112 Installation Manual - page 9
13
14
TESTING
TrOUBLESHOOTING
Testing
Once BREW EXPRESS™ has been installed into the rough-in-box it must be tested to ensure proper operation.
1. Turn on electrical power. Check to see if display panel is illuminated, The display panel is lit when electrical supply
has been properly connected. If the display panel is not lit, refer to the troubleshooting section of this manual.
2. Turn on water supply to BREW EXPRESS™. There should be no leaks in the water connections. If water is
leaking, pull the brewer from the wall, check connections and refer to the troubleshooting section of this manual
to make appropriate corrections. If water is leaking from inside the brewer, disconnect from the rough-in-box
and call for service (866-268-5953).
Test the Brewer
1. Place empty brew basket in unit.
2. Place the empty carafe under brew basket.
3. Set the adjustable cup selector to full carafe.
4. Move the slide switch from OFF to ON.
5. After 30 seconds water will begin flowing and remain on for approximately 7 minutes.
6. A Beeper will sound 40 seconds after water stops flowing.
If the operation does not occur, see the troubleshooting guide in the next section of this manual.
For more detailed information regarding operation, see the OPERATION GUIDE.
Display is not illuminated
•
Ensure the power to the rough-in box is turned on (check circuit breaker).
•
Ensure brewer is fully pressed into the rough-in box.
•
Ensure the outlet inside the rough-in box is properly wired. Remove the brewer
and check outlet with volt meter. If power is on and no voltage is detected at the
outlet, wiring is incorrect. Turn off power. Remove power panel cover (two screws)
and check wire source connection.
•
Check wire connection at source.
Water does not flow from spray head
•
If the BREW EXPRESS™ has not been used for 30 minutes or longer, it will PREHEAT
the water for 30 seconds. You may be waiting for the preheat cycle to end.
•
Ensure water has been turned on to the BREW EXPRESS™ (check valve at source).
•
Ensure the carafe or mug is centered under the brew basket. BREW EXPRESS™
will not start if the detection sensor does not see a carafe or mug. Status light will blink.
The detection sensor may not see a flat black or clear surface. If mug or carafe is flat black
or clear, then switch to a different type of container.
•
Ensure the water line is properly connected inside the rough-in box. Remove The four
mounting screws on the side and pull out brewer. Check for pinched or kinks in the water
supply line. The quick connector from the brewer must be pressed securely into quick
connector from water source.
•
Ensure the water pressure is adequate. The BREW EXPRESS™ will not operate if water
pressure is under 30 PSI. LED display will flash EEEE if water pressure is too low.
•
Check the water filter (if present) at the supply. If filter is clogged replace filter.
•
If problem persists, then coffee system maybe clogged by debris.
Contact Lance Larkin™ for service at (866) 268-5953 or send an email to info@lancelarkin.com
Water overflow from carafe
•
Carafe was not emptied before brew cycle started (empty carafe).
•
Carafe lid is not allowing fluid into carafe. Heat retention door inside lid may be stuck. Remove lid and run warm
water or blow through opening in lid.
•
Flow rate too high, confirm by running 2-3 pots of water, if flow rate is still too high call for technical service.