Troubleshooting
If there is a fault despite due care, this chapter may help you to resolve the malfunction.
Malfunction
Potential causes
Remedy
There is a smell of gas
Leak in the gas system
1. Shut off the cylinder valve
immediately (turn the operat-
ing lever G2 to 3 o'clock posi-
tion).
2. Prevent any flame or spark for-
mation (do not switch on any
electrical appliances)
3. Tighten all connections on the
gas system.
4. Check all components of the
gas system for visible damage;
replace defective parts with
original spare parts
5. Check for leaks using a leak
detector.
Burner does not light
Gas cylinder is empty
Replacing the gas cylinder.
Cylinder valve is closed
Turn the operating lever (G2) to 6
o'clock position
The nozzle on the adjusting ele-
ment (behind front panel) is not
inserted into the burner hose.
Visual check; if necessary adjust
the nozzle and connection hose.
The igniter cable is not on the
Piezo igniter
Visual test, connect if necessary.
Distance between the spark plug
and gas outlets on the burner is
incorrect
Visual test; correct if necessary.
Nozzle on adjusting element
(underneath front panel) is
blocked.
Clean the adjuster jet with a nee-
dle.
Other gas system blocked
Have the gas system cleaned by a
specialist.
Temperature on grill too low
Pre-heating time too short
Close the grill unit lid and set the
flame regulator to max.
Gas outlets on the burner are
blocked
Remove blockage from burner.
Strong flare-up
Fatty foods
Remove any large areas of fat prior
to barbecuing or place the meat on
a grill plate or reduce the barbecue
temperature.
Popping or bubbling noise
Flashback caused by blockages in
the burner.
1. Shut off the cylinder valve
immediately (turn the operat-
ing lever G2 to 3 o'clock posi-
tion).
2. Wait three minutes and then
switch the barbecue back on
3. If the malfunction reoccurs, dis-
assemble and clean the burner.