Lavry DA2002 Operation Manual - Part Iii: Specifications
12
Input Voltage
115V 60Hz or 220V 50Hz, 20 Watts
Warm-up and initial calibration
10 minutes maximum, 3 minutes typical
Consumer outputs 2V R.M.S. into 100k ohms
AES/EBU unbalanced 2.2V R.M.S into 100Kohms
AES/EBU unbalanced 2V R.M.S into 600 ohms
AES/EBU balanced 4.5V R.M.S. into 100Kohms
Analog outputs
AES/EBU balanced 4.2V R.M.S. into 600 ohms
One Consumer, 75 Ohm, transformer isolated
Digital inputs
Two AES/EBU, 110 Ohm, transformer isolated
Phase linearity
2 degrees (10Hz - 20KHz)
Flatness response
+/- .05dB (10Hz -20KHz)
Channel separation
-100dBFs at 1KHz
Crystal lock™ tracking
1ppm / 15 seconds
40-50kHz wide lock mode (varispeed)
Sample rate
96kHx, 88.1kHz, 48kHz, 44.1kHz at +/- 150ppm lock range
10kHz tone at -60dBFS: .00009%FS peak harmonic amplitude
10kHz tone at -1dBFS: .0009%FS peak harmonic amplitude
1kHz tone at -60dBFS: .00009%FS peak harmonic amplitude
Distortion
1kHz tone at -1dBFS: .0009%FS peak harmonic amplitude
Noise
-110dBFS rms, 130dBFS peak spurious response
Part III: Specifications
DA2002