7
load, 2V R.M.S. into 600Ohms.
For Un-balanced XLR connection: The analog output level for a full-scale signal is 2.2V R.M.S. Into 100KOhm
load, 4.2V R.M.S. into 600Ohms.
For Balanced XLR connection: The analog output level for a full-scale signal is 4.5V R.M.S. Into 100KOhm
The analog output level at the IEC connectors for a full-scale signal is 2V R.M.S. into 100KOhm
Analog Output Levels
J10 jumper settings.
The LEFT
OUTPUT
and
RIGHT OUTPUT
IEC signals are always unbalanced and are not effected by J8 and
Pin 1 of the XLR connectors is connected to ground potential for proper cable shield connection.
For Unbalanced mode position the jumpers are set to 90 degrees with respect to the front panel.
The factory default setting is for Balanced outputs-- the jumpers are positioned parallel to the front panel.
J8 and J10 located behind the XLR analog output connectors inside the case.
Operation in unbalanced mode (signal at pin 2 and ground at pin 3) is possible by changing the internal jumpers
(signal between pin 2 and pin 3 of the XLR connectors).
The
LEFT OUTPUT
and
RIGHT OUTPUT
XLR signals are factory set to provide Balanced analog signals
Analog Outputs
Operations Manual