Modern Fan Co aurora flush Installation Instructions Manual - page 6
Antenna
WHITE
BLACK
BLUE
To Motor- Black
WHITE
BLACK
to A/C Power In (Neutral)
#003, #004 and #005 Receiving Unit Wiring Instructions:
With fan suspended from ceiling and with power off at breaker box, make
wire connections as shown below. The receiving unit sits in the ball hanging
bracket of most models as pictured (a), or in the upper portion of the fan
body in Hugger fans, Stratos, Eclipse and Pensi models (b) and (c).
(a)
(b)
(c)
Receiving Unit Placement:
While there is ample room for the receiving unit as shown here, the wires
can sometimes become difficult to manage in the space available. Trimming
excess wire before making connections can ease wire management.
Tip: Splicing lighter gauge wire to the power supply and positioning the
heavier wires up into the junction box can also ease wire management.
(a)
Reminder: Any fan that uses a fluorescent lamp may not be dimmed or
operated with a dimming control. A non-dimming version of our #002
(designated by the suffix “ND”) is available for use with a fluorescent lamp.
For #003/#004/#005, see “Dimming Selection Setting” on next page.
to A/C Power In (Load)
To Neutral(s)- White (& Orange if present)
To Light- Blue