Moen GEC8 Live Owner's Manual - 1- Top View
1- Top view
(2) MUTE/PGM (FS)
(1)
①
② ③ ④ ⑤ ⑥ ⑦ ⑧
(3) BANK/MIDI (PC#)
In RECALL mode, shortly press this button will mute the INPUT and switch guitar to TUNER.
In RECALL mode, these switches recall preset 1~8 separately.
In RECALL mode, this switch changes the bank number.
(4) SEGMENT LED DISPLAY
It is a BANK number indicator(RECALL mode), MODE incidator (REHEARSAL mode), or
“
tens
”
Indicator (MIDI edit mode), or options indicator (SHADOW edit mode).
In REHEARSAL mode, these switches engage/bypass loop1~loop8 individually.
In PROGRAMMING mode, shortly press this button will turn on/off OUT L and OUT R,
(5) FS1 / FS2
Footswitch 1 / 2 indicator, it lights up when footswitch1 / 2 jack is internally open(tip/sleeve).
(9) Indicators of
① ② ③ ④ ⑤ ⑥ ⑦ ⑧
The corresponding indicator lights on when
is pushed.
① ② ③ ④ ⑤ ⑥ ⑦ ⑧
1
3
2
4
5
8 7
6
9
In PROGRAMMING mode, shortly press this button will turn on/off footswitch FS1 and FS2.
The sequence is
“
R(on)L(off)- R(off)L(on)- R&L(on) - R&L(off)
”
In MIDI edit mode, MUTE represents
“
ones
”
9 of a midi PC#.
In MIDI edit mode, it changes the
“
tens
”
of a midi PC#.
(6) MIDI
The indicator flashes when MIDI edit mode or SHADOW edit mode is activated.
(7) OUT R
OUTPUT R indicator, OUT R outputs/mutes signal when the indicator is on/off.
(8) OUT L
OUTPUT L indicator, OUT L outputs/mutes signal when the indicator is on/off.
In SHADOW edit mode, it changes the option number of the midi CC# and FS1.
2
In MIDI edit mode, these switches select
“
ones
”
of a PC#, refer to section 5.3.
In SHADOW edit mode, these switches select options, refer to section 5.4.1.
In SHADOW edit mode, MUTE confirms an option.
Initial active bank number: Hold BANK switch then power up GEC8 live, the bank number starts to
blink, press BANK to choose active bank number (2~10), hold BANK for 2s to finalize initialization.