N-Tron 102MC User Manual & Installation Manual - page 6
(Revised 2010-11-15)
6
DIN-Rail Mounting
Install the unit on a standard 35mm DIN-Rail. Recess the unit to allow at least 5” of horizontal clearance for the fiber optic cable
bend radius.
To install the unit to 35mm industrial DIN-Rail, place
the top edge of the included mounting bracket on the back
of the unit against the DIN-Rail at a 15° angle as shown.
Rotate the bottom of the unit to the back (away from you)
until it snaps into place.
To remove the unit from the 35mm industrial DIN-Rail,
place a flat head screwdriver into the orange release clip
found at the bottom of the unit, and apply downward force
on the clip until it disengages from the bottom of the unit
from the DIN-Rail. Rotate the bottom of the unit towards
you and up at an approximate 15° upward angle to
completely remove the unit.
300-PM
900-PM
URMK
With the exception of the 524TX and
526FX2, all N-Tron™ products are designed
to be mounted on industry standard 35mm
DIN-Rail. However, DIN-Rail mounting may
not be suitable for all applications. We offer
three alternative mounting solutions: Our 300
Panel Mount Assembly (P/N: 300-PM) may
be used to mount a single 100 or 300 Series
unit to a panel or other flat surface. Our 900
Panel Mount Assembly (P/N: 900-PM) may
be used to securely mount our 100, 200, 300,
400, 500, or 900 Series products to a panel or
other flat surface; Our Universal Rack Mount
Kit (P/N: URMK) may be used to mount our
products to standard 19" racks.