Napoleon GI 3600-N Installation And Operating Instructions Manual - page 6
6
W415-0061 / C / 10.25.11
An on/off switch has been included and can be located at
the right side trim.
For ease of accessibility, this switch may
be replaced with a wall switch or substituted with a millivolt
thermostat that may be installed in a convenient location on
any wall. Route a 2 strand solid core millivolt wire through the
electrical hole located at the bottom right side of the unit. The
recommended maximum lead length depends on wire size:
WIRE SIZE
MAX. LENGTH
14gauge
100
feet
16gauge
60
feet
18gauge
40
feet
Attach the two leads to terminals 1 and 3 located on the gas
valve.
Do not connect the gas valve to electricity (110 volts or
24 volts).
FIGURE 5
FIGURE 4
1
2
3
The insert can be equipped with a fl ashing kit to close off
most fi replace openings. Mount the fl ashing inside the unit's
outer shell using 4 securing screws. The fl ashing and trim are
available in many fi nishes to accent any room decor. Objects
placed in front of the fi replace should be kept a minimum of
48" away from the front face.