National Security Systems D360 User Manual - page 24
To use Selective Zone Shunting:
1. Ensure that all zones are secure.
2. Start the system exit delay by entering your personal passcode or an
arming command which provides exit delays. The PERIMETER and
INTERIOR lights flash, indicating the start of the exit delay time.
3. While the system is in the exit delay mode, press the
COMMAND
bar. The system is now in the Selective Zone Arming mode. (Priority
and 24 hour zones cannot be bypassed.)
CAUTION:
You are in the exit delay mode and only have a limited
amount of time in which to complete this operation.
4. To
prevent
a zone from being armed, press the key that corresponds
with the number of that zone. For examole, to prevent zone 4 from
being armed, simply press the 4 key. after the 4 key is pressed,
the indicator light for zone 4 is illuminated indicating the zone is
shunted.
During the exit time, if a bypassed zone is to be armed with the rest of
the system, press the key that corresponds to the zone, the indication
light for that zone will go off.
Selective Zone Shunting
I have this feature.
I do not have this feature.
Selective Zone Shunting
will
be reported to the Central Station.
Selective Zone Shunting
will not
be reported to the Central Station.
The Command Center makes it easy for you to have complete control over
your security system. By using Selective Zone Shunting you have the
ability to bypass zones you do not wish to arm, directly from the Command
Center. If you don’t want a particular zone to arm simply push the same
numbered key as that zone, and it will not arm with the rest of the system.
Application
In an office building or warehouse, Selective Zone Shunting enables you
to arm only those areas that need to be kept secure. Areas where personnel
are working can be kept disarmed until they are finished and the areas
vacated. To arm all zones, simply disarm the unit and rearm using
COMMAND 1 or your personal passcode.