North Road Technologies Geyser 6000–3.0 Installation & Owner's Manual - page 10
Then apply thread seal tape to both
ends of the brass fitting with the
plastic water in-feed tube (Item
105), and insert/screw the fitting
into the front end of the ‘‘T”, and
tighten snugly. Make sure plastic
slides in freely, without obstructions
in the tank. On some electric tanks (such as Marathon) there
will be obstructions within the tank due to the configuration of
the piping within the tank. If the plastic in-feed tube does not
enter the tank freely, please stop, and consult with a professional
installer.
Now, insert the second brass
“T” fitting, (item 103), onto
the exposed end of the pipe,
again leaving the “T” in the
approximate vertical position.
Install the discharge valve removed
from the tank earlier onto the
exposed end of the fittings.
Next, apply thread seal tape to, and
install a valve, (item 104), onto the “T”
fitting closest to the tank, making sure
it is tight.
—10—
—11—
After
the nipple, (Item 102) is
properly installed on the tank,
make a connection between the
thermistor leads and the GEYSER
leads. Insert one of the thermistor
leads and one of the Geyser leads
into the connector, as shown
on the photo. Insert one wire
from each of the two temperature
sensor cables into one end of
the red “UR” connectors found in the installation
kit. The ends should already have been split apart
approximately 1” (2.5cm).
The wire insulation does
not need to be stripped, the “UR” connector will
connect through the insulation.
Squeeze the “UR” connector with a pair
of pliers, or tap gently with a hammer.
Do not use unneccessary force when
squeezing the red “UR” connector.
The
red “button” on the connector will be
pressed in until it is even with the top
of the connector.
Repeat this step with the remaining two leads.
The finished version will have the
thermistor connected to the nipple
and then to the Geyser. This will
allow the Geyser to sense the tank
temperature and operate properly.
Next, insert one of the two brass “T” fittings,
(item 103) onto the exposed end of the nipple, and
tighten snugly. Leave the open “T” approximately
in the vertical position.