North Road Technologies Geyser 6000–3.0 Installation & Owner's Manual - page 3
SECTION 6–HEAT PUMP WATER HEATER MAINTENANCE
WARNING
BEFORE SERVICING THE EXISTING GEYSER, OR THE ELECTRIC WATER HEATER, UNPLUG THE UNIT(S),
TURN OFF CIRCUIT BREAKER OR REMOVE THE FUSES
SUPPLYING POWER TO THE WATER HEATER. FAILURE TO DO SO MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR DEATH.
GEYSER Internal Wiring Diagram
The GEYSER 6000–3.0™ from North Road Technologies requires very little in the
way of maintenance to ensure a long and trouble free life for your unit.
AIR FILTER—
The air filter should be cleaned whenever visibly dirty. The air filter is another
benefit provided by the GEYSER 6000–3.0™. It cleans the air at no additional cost. It is a
critically important component of the GEYSER 6000–3.0 and will significantly reduce the
heating capacity and efficiency when dirty. The filter can be cleaned by gently hand-washing
in water. Remove and replace with care. Replacement air filters can be purchased through North
Road Technologies at
www.northrdt.com
.
EVAPORATOR
—
The evaporator underneath the air filter becomes clogged or dirty, it may
be cleaned either by vacuuming or with a commercial evaporator cleaning spray. DO NOT use a
solvent containing bleach, acetone, or flammable substances. TURN THE UNIT OFF AT THE FUSE
OR BREAKER BOX BEFORE CLEANING.
DRAIN AND FLUSH—
Drain five gallons of water from the tank every six months. Connect a
garden hose to the drain valve at the bottom of the tank, and put the other end of the hose
where you want the drained water to go. Close the stop valve that is right next to the drain
valve, and open the drain valve. This will drain some water from the tank and back-flush the
Heat Pump Water Heater. After five gallons have been drained, close the drain valve, open the
stop valve and remove the hose. This practice will extend the life of both the GEYSER 6000–
3.0 and the storage tank.
Stop GEYSER 6000–3.0™ by pressing the selector switch rocker to OFF.
This will
allow the resistance elements in the tank to heat the water until the GEYSER 6000–3.0 is
repaired. Press the selector switch rocker to off and call for service.
—3—
—18—
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENC
E!
(for
the life of the unit)
Please be sure to read and follow all instructions carefully before
attempting to install or
operate the Geyser 6000–3.0™.
http://
www.northrdt.com