NoSquito NT200 Operation Manual - General Safety Instructions
(Read before unpacking and operating the NOsquito Outdoor Mosquito Trap.)
1. Only use an outdoor extension cord having a 3-prong plug and receptacle that accepts the NOsquito Outdoor
Mosquito Trap's plug. The Trap has a 3-conductor cord and a 3-prong grounding type plug to fit a properly
GFCI protected grounded outlet.
2. The electrical rating of the extension cord must be greater than or equal to the electrical rating of the Trap
(120 Volt / 0.6 Amp). Use an extension cord with 16 gauge or thicker wire and that has a label stating it is
suitable for outdoor use.
3. Do not abuse any electrical cord. Never yank it to disconnect from the receptacle. Keep all cords away from
heat, flammable substances and sharp objects. Replace damaged cords.
4. The connections between the Trap and the extension cord must always remain dry and kept off of the ground.
5. Disconnect the Trap from the power supply when not in use, changing propane tanks, before servicing and/or
cleaning.
6. Do not insert foreign objects into this product.
7. To avoid electric shock, DO NOT clean the Trap by spraying water or by immersing any Trap part in water.
8. All repairs to the Trap must be performed only by qualified service personnel.
9. Read and follow all instructions listed on the burner assembly.
10. Young children should be carefully supervised when they are in the area of the Trap.
11. Clothing or other flammable materials should not be hung from or placed on or near the Trap.
12. Any guard or other protective device removed for servicing the Trap must be replaced prior to operating.
13. It is imperative that the compartment, burner and circulating air passageways of the Trap be kept clean at
all times.
14. A maximum of a 20 lb. LP-Gas cylinder shall be used with the Trap. (Can not be used with natural gas.)
15. Use standard 20 pound LP-Gas cylinder with a shutoff valve terminating in an LP-gas supply cylinder valve
outlet specified for Connection No. 791 in the Standard for Compressed Gas Cylinder Valve Outlet and Inlet
Connections, ANSI/CGA-V-1 latest edition (any standard propane tank manufactured in the USA after 1999).
16. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 for US and with the CAN1-B149 for Canada. The LP-Gas cylinder used shall be
constructed and marked in accordance with the specifications for LP-Gas cylinders of the U.S. Department
of Transportation (DOT).
17. This Trap is not intended to be installed in or on recreational vehicles and/or boats.
18. Do not place the Trap under overhead unprotected combustible construction. Maintain a minimum of 5 feet
clearance around the perimeter of the Trap when in use.
19. Inspect the hose before each use of the Trap. If it is evident there is excessive abrasion or wear, or the
hose is cut, it must be replaced prior to operating the Trap. The replacement hose shall be that specified
by the manufacturer.
20. Retain this instruction manual for future reference.
21. This Trap shall be used outdoors and only in a well-ventilated space and shall not be used in a building,
garage or any other enclosed area.
22. The Trap should be stored indoors when not in use and kept away from children.
23. If the Trap is not in use, the gas must be turned off at the supply cylinder. Storage of the Trap indoors is
permissible only if the cylinder is disconnected and removed. Cylinders must be stored outdoors out of reach
of children and must not be stored in a building, garage or any other enclosed area.
24. The pressure regulator and hose assembly supplied with the Trap must be used for connection to the LP-Gas
cylinder. Replacement pressure regulators and hose assemblies must be provided by Kaz, Inc.
GENERAL SAFETY INSTRUCTIONS
4