Novatek Volt Control RN-122 Operating Manual - page 5
~ 5 ~
RN-122
NOVATEK-ELECTRO
Check the device for absence of damage after transportation; in case of such damages detection, contact
the supplier or the manufacturer;
Carefully study the Operating Manual;
If you have any questions regarding the installation of the device, please contact the manufacturer by
telephone number indicated at the end of this Operation Manual.
3.1.2. Device connection
3.1.2.1. Connect RN-122 to the
mains socket.
Display will briefly indicate
the inscription
“
”
Then display will show
AR countdown
Upon completion of AR countdown,
the value of the mains voltage will
be displayed, the voltage will
appear in the RN-122 socket, the
ON LED will light up
The device is ready for operation.
If the mains voltage exceeds set thresholds, the display will show the value of the mains voltage in the blinking
mode instead of the AR countdown, in this case there is no voltage in the device socket, the ON LED is off.
After restoring the mains voltage parameters, the display will show the mains voltage value, the voltage will
appear in the RN-122 socket, the ON LED will light up.
3.1.2.2. The device has the following factory settings:
If the factory settings of the device do not suit you, set them according to it. 3.1.3.
3.1.2.3.
Connect the protected equipment to the socket of RN-122.
3.1.3. Device parameters setting
3.1.3.1. Setting the minimum voltage operation threshold
Press Umin/- button
– the display
will show the factory setting of the
parameter with flashing dots
(1.8.5.)
Press Umin/- or Umax/+ buttons
to change the parameter value
from 160 to 210 V in increments
of 5 V
The parameter will be saved
automatically 5 s after the last push
of the buttons. After saving, the
display will show the value of the
mains voltage
3.1.3.2. Setting the maximum voltage operation threshold
Max. voltage operation threshold
250 V
Min. voltage operation threshold
185 V
On-time after voltage failure (AR interval)
5 s