Officezone RHIN-O-TUFF OD 3500 Instruction Book - page 28
Diagram 9
12) Attaching the Versa Switch to OD 4000: Diagram 9
The versa switch replaces the foot pedal and paper stop. By pushing the paper
against this switch, it positions the paper in the correct location so the holes are
centered in the sheet and also activates the punch.
Unplug the main power cord from the OD 4000 punch.
Remove the foot pedal plug from the left side of the OD 4000 punch.
Install the versa switch plug into the same receptacle that the foot pedal plug
was removed from.
Remove the paper stop from the front cover of the OD 4000.
The Versa switch comes fully assembled. The knob (1) will have to be
removed from the assembly. Also, the two wires (2) attached to the switch
will have to be removed.
Place the switch bracket (3) inside the cover (4) and the paper stop through
the slot of the cover. Use the knob to attach the assembly back to the original
configuration.
Reattach both wires to the same terminals of the switch.