OHAUS 4000W Series Instruction Manual - Valor

Other manuals for 4000W Series: Instruction Manual

Summary of 4000W Series

  • Page 1

    Valo r™ 4000w series instruction manual.

  • Page 3: Valo

    Valo r™ 4000w series en-1 1. Introduction this manual contains installation, operation and maintenance instructions for the valor™ 4000w series. Please read the manual completely before using the scale. 1.1 safety precautions please follow these safety precautions: verify that the ac adapter input v...

  • Page 4: En-2

    En-2 valo r™ 4000w series 2.3 selecting the location use the scale on a clean, firm and flat surface. Avoid locations with excessive air current, vibrations, heat sources, or rapid temperature changes. 2.4 leveling the equipment adjust the leveling feet so the bubble is centered in the circle. Be su...

  • Page 5: Valo

    Valo r™ 4000w series en-3 2.5.1 battery power: the scale can be used on ac power immediately. Allow the battery to charge for 12 hours before using the scale on battery power. The scale will automatically switch to battery operation if there is a power failure or the power cord is removed. With ac p...

  • Page 6: En-4

    En-4 valo r™ 4000w series 3. Operation 3.1 controls figure 3-1. Front control panel valor 4000w with display table 3-1 button functions short press 1 (when on): sets display to zero short press (when off): turns scale on long press 2 (when on): turns the scale off short press (in menu): selects / ac...

  • Page 7: Valor

    Valor ™ 4000w series en-5 display table 3-2 display symbols item description item description 1 net symbol 9 calibration / menu mode symbol 2 center of zero symbol 10 dynamic symbol* 3 negative symbol 11 battery charge symbol 4 stable weight symbol 12 pound, ounce, pound:ounce symbol 5 preset tare s...

  • Page 8: En-6

    En-6 valo r™ 4000w series 3.2 turning scale on/off to turn the scale on, press the on/zero off button. The scale performs a display test, momentarily displays the software version, and then enters the active weighing mode. To turn the scale off, press and hold the on/zero off button until off is dis...

  • Page 9: Valor

    Valor ™ 4000w series en-7 3.5 percent mode this mode measures the weight of a sample as a percentage of a reference weight. 1. Press and hold mode until [percnt] is displayed. [clr.Ref](clear reference) will then display. Notes: press function to view the current reference weight. If there is no ref...

  • Page 10: En-8

    En-8 valo r™ 4000w series 3.7 accumulation accumulation works together with each application mode. This function allows the user to store the total of a series of weight measurements. 1. Press the m+ key to add the weight to the accumulation data. The Σ icon will keep flashing until the weight is re...

  • Page 11: Valor

    Valor ™ 4000w series en-9 4. Menu settings the user menu allows the customizing of scale settings. 4.1 menu navigation user menu: menu: c.A.L s.E.T.U.P r.E.A.D m.O.D.E u.N.I.T l.O.C.K e.N.D menu items: span lin geo end reset pwr.Un a.Tare ir.Func ir.Adj accum end reset stable filter azt light sleep ...

  • Page 12: En-10

    En-10 valo r™ 4000w series 4.3 setup menu enter this menu to set scale parameters. Reset [reset] (no, yes) reset the setup menu to factory defaults. Power on unit [pwwr.Un] (auto, kg, g, lb, oz, lb:oz) set the unit of measure displayed at startup auto tare [a.Tare] (off, on, on-acc) set the automati...

  • Page 13: Valor

    Valor ™ 4000w series en-11 4.5 mode menu enter this menu to activate modes so they will be available for use with the mode button. Weigh mode is always active by default. Reset [reset] (no, yes) reset the mode menu to factory defaults. Percent [percnt] (off, on) set the status. Check [check] (off, o...

  • Page 14: En-12

    En-12 valo r™ 4000w series table 4-1. Geo codes 0 325 650 975 1300 1625 1950 2275 2600 2925 3250 325 650 975 1300 1625 1950 2275 2600 2925 3250 3575 0 1060 2130 3200 4260 5330 6400 7460 8530 9600 10660 1060 2130 3200 4260 5330 6400 7460 8530 9600 10660 11730 0°00' 5°46' 5 4 4 3 3 2 2 1 1 0 0 5°46' 9...

  • Page 15: Valor

    Valor ™ 4000w series en-13 4.9 legal for trade when the scale is used in trade or a legally controlled application it must be set up, verified and sealed in accordance with local weights and measures regulations. It is the responsibility of the purchaser to ensure that all pertinent legal requiremen...

  • Page 16: En-14

    En-14 valo r™ 4000w series 4.9.3 verification and sealing the local weights and measures official or authorized service agent must perform the verification procedure. 4.9.3.1 physical seals for jurisdictions that use the physical sealing method, the local weights and measures official or authorized ...

  • Page 17: Valor

    Valor ™ 4000w series en-15 the audit trail information is displayed in the format cfgxxx and calxxx. The scale then returns to normal operation. 5. Maintenance 5.1 cleaning the housing may be cleaned with a cloth dampened with a mild detergent if necessary. Do not use solvents, chemicals, alcohol, a...

  • Page 18: En-16

    En-16 valo r™ 4000w series 5.3 troubleshooting the following table lists common problems and possible causes and remedies. If the problem persists, contact ohaus or your authorized dealer. Table 5-1 symptom possible cause remedy cannot turn on no power to scale battery discharged verify connections,...

  • Page 19: Valor

    Valor ™ 4000w series en-17 6.1 specifications table 6-1 model v41pwe1501t v41xwe1501t v41pwe3t v41xwe3t v41pwe6t v41xwe6t v41pwe15t v41xwe15t capacity x readability (max x d non-approved) 1.5 kg x 0.0002 kg 1500 g x 0.2 g 3 lb x 0.0005 lb 48 oz x 0.01 oz 3 kg x 0.0005 kg 3000 g x 0.5 g 6 lb x 0.001 ...

  • Page 20: En-18

    En-18 valo r™ 4000w series 6.3 compliance compliance to the following standards is indicated by the corresponding mark on the product. Mark standard this product conforms to the emc directive 2004/108/ec, the low voltage directive 2006/95/ec and the non-automatic weighing instrument directive 2009/2...

  • Page 21: Valor

    Valor ™ 4000w series en-19 disposal in conformance with the european directive 2002/96/ec on waste electrical and electronic equipment (weee) this device may not be disposed of in domestic waste. This also applies to countries outside the eu, per their specific requirements. The batteries directive ...

  • Page 22: En-20

    En-20 valo r™ 4000w series limited warranty ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period ohaus will repair, or, at its option, replace any component(s) that proves to be def...