Panasonic CS-E15DD3EW Service Manual - page 22
8.1.7. Outdoor Fan Motor Operation
Outdoor fan motor is operated with 15 fan speed. It starts when compressor starts operation and it stops 30 seconds after
compressor stops operation for speed no.8.
No.
RPM during Fan Speed (rpm)
E18D
E15D
15
73
71
14
73
71
13
68
66
12
66
64
11
62
60
10
60
60
9
58
58
8
50
50
7
45
45
6
40
40
5
35
35
4
30
30
3
25
25
2
20
20
1
15
15
8.1.8. Quiet operation (Cooling Mode/Cooling area of Dry Mode)
A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
• When “quiet” button at remote control is pressed.
Quiet LED illuminates.
b. Quiet operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c.
Timer “off” activates.
d. Quiet button is pressed again.
2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
22
CS-E15DD3EW CU-E15DBE / CS-E18DD3EW CU-E18DBE