IMPORTANT: DO NOT FIT A FUSE WITH A HIGHER RATING.
NOTE: that fuse failure may indicate a severe problem. Check all speakers and
speaker cables for damage etc. Should the amplifier continue to exhibit rail fuse
failure, contact your Plinius dealer.
MAINS/LINE FUSE
A Mains/Line fuse is fitted within the IEC socket on the rear of the amplifier. A small
drawer at the bottom of this socket may be removed (after the IEC plug is removed)
by levering it out with a flat blade screwdriver. The fuse fitted should be rated as
specified on the rear panel.
IMPORTANT: DO NOT FIT A FUSE WITH A HIGHER RATING.
In the unusual event that this fuse should blow, you must first establish the cause of
this failure (such as power surges, damaged mains cable, etc) before replacing the
fuse with one of the same rating and type. Should the amplifier continue to suffer
mains fuse failure, contact your Plinius dealer.
OVER TEMPERATURE PROTECTION
The Plinius 9200 is fitted with an auto-reset thermal sensor. The sensor is located at
the main power transformer and should the transformer internal temperature exceed
110°C (230°F) the power will be disconnected from the unit.
The unit will remain off until the temperate has reduced significantly, and then the
sensor will automatically reset to the ON state.
If Over Temperature Protection occurs you should switch the unit off immediately. Check
the placement of the unit and ensure there is adequate airflow above and around the
unit. Refer to the Placement & Ventilation section on page 4 for further information.