Plum ecoSTER TOUCH Operation And Assembly Manual

Manual is about: ROOM PANEL FOR ECOMAX BOILER CONTROLLER

Summary of ecoSTER TOUCH

  • Page 1

    Room panel ecoster touch for ecomax boiler controller operation and assembly manual issue: 1.0 software version: v01.Xx.Xx 10-2015.

  • Page 3

    Contents 1. General information and safety ............... 4 2. Application....................................................... 4 3. Operation ......................................................... 4 3.1 o peration of the panel ..................................... 4 3.2 m ain screen ............

  • Page 4

    4 1. General information and safety  incorrect electrical connection between the room panel and ecomax controller may result in damage to both devices.  assembly has to be carried out by a qualified installer.  use additional precautions in order to prevent the effects of controller malfunctions ...

  • Page 5

    5 3.2 main screen 1. Name of the device defined by the user. 2. Current measured temperature inside the compartment. 3. Room thermostat work mode: schedule, economy, comfort, out of home, airing, party, holidays, antifreeze, loading huw 4. Active thermostat signaling (heating). 5. Symbol of the sele...

  • Page 6

    6 operating before the outside home mode was set. Symbol is displayed on the screen. 3.3.5 airing selection of this mode will result in closing the mixing valves and switching the circulating pumps off in the boiler controller for a preprogrammed period of 1÷60min. After this mode is activated, its ...

  • Page 7

    7 set the comfort (day) or economic (night) temperature with the use of button. Set the indicator “2” to an ending hour of time zone with the use of , > buttons, press button in order to finish editing the zone, the aforementioned actions can be repeated for other time period, if required press butt...

  • Page 8

    8 3.12.3 screen brightness enables setting screen backlight brightness in [%] separately for a day (6:00- 22:00), night (22:00-6:00) and the current edition of settings. 3.12.4 changing the language enables changing the language of the room thermostat. 3.12.5 parental lock this function activates it...

  • Page 9

    9 etc. It facilitates determining location of the panel inside the building and changing preset temperature in a distant room. This name will be additionally visible on screens of other room panels. Selected panel address (at 2 or 3 connected panels) is displayed on the main screen as (further digit...

  • Page 10

    10 4. Assembly 4.1 technical data power supply/consumed current +12vdc/150ma protection class ip20 work/storage temperature 0..50/0..65 c temperature measurement/regulation range 0..50/5..35 c hysteresis 0.2..5 c relative humidity 5 - 85%, without condensation display graphic, touch dimensions 148x9...

  • Page 11

    11 4.5 electrical connection with ecomax controller module recommended supply voltage of the room panel is +12vdc. Panel can be supplied with +5÷12v. However, it is not recommended due to voltage losses in long connection wires. 4-wire cable with a max. Length of 30m and cross-section of ≥ 0.5 mm 2 ...

  • Page 12

    12 4.5.2 connection with ecomax800 p3, d3 and ecomaxx800 r3, t3 controller module can supply up to 2 colored touch type panels simultaneously. If the boiler controller is equipped with a standard control panel (version with a knob), two ecoster touch room panels can be supplied directly from the con...

  • Page 13

    13 4.5.4 connection with ecomax850p2, r2, d2 controller module can supply up to 2 colored touch type panels simultaneously if the boiler controller is equipped with a standard control panel (version with a knob), two ecoster touch room panels can be supplied directly from the controller module (term...

  • Page 14

    14 4.5.5 connection with ecomax860p1, d1 controller module can supply up to 2 colored touch type panels simultaneously. If the boiler controller is equipped with a standard control panel (version with a knob), two ecoster touch room panels can be supplied directly from the controller module (termina...

  • Page 15

    15 4.5.6 connection with ecomax860p2, d2 5. Controller module can supply up to 2 colored touch type panels simultaneously. If the boiler controller is equipped with a standard control panel (version with a knob), two ecoster touch room panels can be supplied directly from the controller module (sock...

  • Page 16

    20 office@feroterm.Ro www. Feroterm.Ro tel: 0264 241 234 str.Armeneasca,nr. 59,gherla,jud.Cluj plum@plum.Pl www.Plum.Pl www.Plumelectronics.Eu.