Plum ecoSTER TOUCH Operation And Assembly Manual - page 12
12
4.5.2 Connection with ecoMAX800 P3,
D3 and ecoMAXX800 R3, T3
Controller module can supply up to
2 colored TOUCH type panels
simultaneously.
If the boiler controller is equipped with a
standard control panel (version with a knob),
two ecoSTER TOUCH room panels can be
supplied directly from the controller module
(terminal 31). Third panel has to be
supplied by the additional power adapter
+12V, I≥0.5A.
If the boiler controller is equipped with
ecoTOUCH control panel (colored with a
touch panel), only one ecoSTER TOUCH room
panel can be supplied directly from the
controller module (terminal 31). Panels 2
and 3 have to be supplied by the additional
power adapter +12V, I≥0.5A.
4.5.3 Connection with ecoMAX850P1,
R1, D1
All 1,2,3 room panels require application of
an additional power adapter +12VDC,
I≥0.5A.