Plum ecoSTER TOUCH Operation And Assembly Manual - page 14
Manual is about: ROOM PANEL FOR ECOMAX BOILER CONTROLLER
of
16
14
4.5.5 Connection with ecoMAX860P1,
D1
Controller module can supply up to
2 colored TOUCH type panels
simultaneously.
If the boiler controller is equipped with a
standard control panel (version with a knob),
two ecoSTER TOUCH room panels can be
supplied directly from the controller module
(terminal 46). Third panel has to be
supplied by the additional power adapter
+12V, I≥0.5A.
If the boiler controller is equipped with
ecoTOUCH control panel (colored with a
touch panel), only one ecoSTER TOUCH room
panel can be supplied directly from the
controller module (terminal 46). Panels 2
and 3 have to be supplied by the additional
power adapter +12V, I≥0.5A.
e
co
M
A
X86
0
eco
M
A
X86
0