Protherm Leopard 24 BOV User And Installation Instructions Manual - Water Temperature Setting
5
Actual circuit heating water tem-
perature indication in °C.
LED 3 under symbol
lights continuously. The
actual temperature of he-
ating water flowing from
boiler is displayed.
Domestic hot water temperature
indication in °C (required value).
Domestic hot water tap is
open. LED 2 under sym-
bol lights continuous-
ly. DHW temperature co-
rresponds with required
value in certain DHW flow
range.
Water pressure in central heating
system in Bar.
LED 1 under symbol
lights continuously. Re-
commended range is
1 - 2 Bar. Pressure is
displayed for 30 sec.
after
one pressing
button.
Domestic hot water temperature
setting in °C.
Temperature is displayed
for 30 second after
two
pressing
button,
LED 2 under symbol
flash.
Buttons set domestic water tem-
perature to following values: 35, 37, 38,
39, 40, 41, 44, 47, 50, 55, 60°C. Setting
symbol means no preparation do-
mestic hot water.
Setting value are saved into memory
after next pressing button (if it's
not confirmed until 30 sec., the previous
setting is saved again)
Circuit heating water temperature
setting in °C.
Temperature is display-
ed for 30 sec. after
three
pressing
button,
LED 3 under symbol
flash.
Buttons set central heating water
temperature to following values: 38, 40,
42, 45, 50, 55, 60, 65, 70, 75, 80°C. Set-
ting symbol switches central heating
off (SUMMER adjustment).
Setting value are saved into memory
after next pressing button (if it's
not confirmed until 30 sec., the previous
setting is saved again).
Boiler indication during ordinary operation (display mode)
Water temperature setting
Warning on wrong pressure in he-
ating system under value 1 Bar (or
over 2,5 Bar).
Boiler still works. LED 1
under symbol flash. It
is necessary to fill up (or
drain) the heating sys-
tem to pressure 1- 2 Bar
soon.