Protherm Tiger 24 (12) KTZ Operating And Installation Manual

Manual is about: Wall-hang combined boiler

Summary of Tiger 24 (12) KTZ

  • Page 1

    Supplied by www.Heating spares.Co tel. 0161 620 6677 1 table of contents introduction ............................................2 operating guide controls and signals ..............................4 selecting read mode ............................5 selecting setup mode ...........................5...

  • Page 2: Boiler Operating and

    Supplied by www.Heating spares.Co tel. 0161 620 6677 protherm spol. S r.O. Pplk. Pľjušťa 45 909 01 skalica tel.: 034 6966 101 fax: 043 6966 111 www.Protherm.Sk your service: boiler operating and installation guide 24 (12) ktz / v.17 24 (12) koz / v.17 wall-hang combined boiler output 9,5 - 23 (3,5 -...

  • Page 3: Introduction

    Supplied by www.Heating spares.Co tel. 0161 620 6677 2 1. The boiler and all associated equipment must be installed and used in accordan- ce with the installation design, all appli- cable legal regulations, technical stan- dards and with the manufacture’s in- structions. The boiler may be used only ...

  • Page 4

    Supplied by www.Heating spares.Co tel. 0161 620 6677 3 situations might occur in practice, when the following essential measures must be adopted: • prevent the boiler from (even accidental- ly) being turned on while conducting in- spections or working on the combustion gasses flue route or gas and wa...

  • Page 5: Operating Guide

    Supplied by www.Heating spares.Co tel. 0161 620 6677 4 operating guide operating guide controls and signals main switch the main switch (fig. 1) is used to switch the boiler on or off. The main switch is si- tuated on the bottom side of the boiler in line with the control panel. Please note: the boi...

  • Page 6: Displaying Hew Pressure

    Supplied by www.Heating spares.Co tel. 0161 620 6677 5 displaying hew pressure pressing and holding de- pressed the but- ton will display hew pres- sure (bar) in the system for about 30 s. The led at symbol lights up. Warning “hew pressure too low” when the hew pressure drops below 0.8 bar or rises ...

  • Page 7: Heating

    Supplied by www.Heating spares.Co tel. 0161 620 6677 6 setting time intervals for water tank heating the tiger boiler enables setting of how heating in the tank in various time inter- vals. Example: if hot water is not used in the night, how heating may be switched off (or vice versa) for a given ti...

  • Page 8: Equithermal Mode – Curve

    Supplied by www.Heating spares.Co tel. 0161 620 6677 7 equithermal mode – curve steepness press the button repeatedly until the dis- play shows the letter e with parameter 0 to 9. Use buttons to select the equithermal curve. The curve steepness increases with the set number (e0 saving to the memory ...

  • Page 9: Boiler Function Flowchart

    Supplied by www.Heating spares.Co tel. 0161 620 6677 8 fig. 5 boiler function flowchart.

  • Page 10: Loss of Hew Pressure - F0

    Supplied by www.Heating spares.Co tel. 0161 620 6677 9 loss of hew pressure - f0 loss of hew pressure (under 0.6 bar) in the system. The boiler is automatically shut down – leds at symbols and are flashing. Add heating water to the system to pressure at 1 - 2 bar. After adding heating water to the sy...

  • Page 11: Starting The Boiler Up

    Supplied by www.Heating spares.Co tel. 0161 620 6677 10 starting the boiler up important: putting the boiler into operati- on and starting it up for the first time must be done by an authorised service only! If you wish to start the boiler after it has been put into operation, make sure that: 1. The ...

  • Page 12: Control

    Supplied by www.Heating spares.Co tel. 0161 620 6677 11 rature of the water in the system) which will be capable of covering thermal losses of the building even in low outdoor tempe- ratures. We recommend selecting a tem- perature in the 60 – 80 °c range. Using the boiler with equithermal control th...

  • Page 13: Protection Against Freezing

    Supplied by www.Heating spares.Co tel. 0161 620 6677 12 example: select curve e5. At an outdoor temperature of -10 °c the boiler provides the heating system with a temperature of 70 °c. If the reference temperature shift parameter p5 is selected at the same time, then at an outdoor temperature of 15...

  • Page 14: Pump Run-Down

    Supplied by www.Heating spares.Co tel. 0161 620 6677 13 pump run-down pump run-down is factory set to 45 se- conds after termination of the command from the room control unit. If the boiler is run without a room control unit, the pump runs continuously. If this mode is not acceptable, a second setti...

  • Page 15: Cleaning

    Supplied by www.Heating spares.Co tel. 0161 620 6677 14 cleaning the boiler cover can be cleaned with a moist cloth and afterwards dried and po- lished with a dry cloth. Never use abrasive detergents or solvents. Important: before cleaning the boiler, turn it off with the main switch. Regular servic...

  • Page 16

    Supplied by www.Heating spares.Co tel. 0161 620 6677 15 technical parameters 24 (12) koz tiger 24 koz tiger 12 koz category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ii 2h3p version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 17

    Supplied by www.Heating spares.Co tel. 0161 620 6677 16 technical parameters 24 (12) ktz tiger 24 ktz tiger 12 ktz category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ii 2h3p version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 18: Boiler Connection Dimensions

    Supplied by www.Heating spares.Co tel. 0161 620 6677 17 boiler connection dimensions připojovací rozměry kotle usable gauge pressure to the system 1. Hew outlet g3/4“ 2. How outlet g1/2“ 3. Gas inlet g1/2“ 4. How inlet g1/2“ 5. Hew inlet g3/4“ 6. Tank drain fig. 7 fig. 8.

  • Page 19: Function Schematic Diagram

    Supplied by www.Heating spares.Co tel. 0161 620 6677 18 1*. Combustion gas thermostat 9. How draining valve 19. Bypass 1. Air manostat 10. Hew safety valve 20. 3-way motor valve 2*. Draught valve 11. Hew inlet 21. Draining valve 2. Fan 12. How inlet 22. Pressure sensor 3. How tank insulation 13. Gas...

  • Page 20: Introduction

    Supplied by www.Heating spares.Co tel. 0161 620 6677 19 cium and magnesium concentration greater than 1.8 mmol/l, it is useful to implement other “non-chemical” measures against incrustation (e.G. Magnetic water treatment combined with a desludging device). Problems caused by clogging of the system ...

  • Page 21

    Supplied by www.Heating spares.Co tel. 0161 620 6677 20 the manipulation (free) space left around the boiler must be sufficient for a person to work on it safely with bare hands and with common hand tools. Recommended distances are min. 300 mm from each side and min 600 mm in front of the boiler). Bo...

  • Page 22: Boiler Delivery

    Supplied by www.Heating spares.Co tel. 0161 620 6677 21 boiler delivery protherm tiger 24 (12) ktz and 24 (12) koz boilers are delivered completely assembled and functionally tested. The delivery contains (fig. 11): 1. Boiler 2. Operations and installation guide 3. Service book 4. List of service ce...

  • Page 23: Distribution Pipes

    Supplied by www.Heating spares.Co tel. 0161 620 6677 22 distribution pipes nominal pipe inside diameter is chosen in the usual way based on the pump chara- cteristic. Distribution pipes are designed according to the requirements on system performance, not according to the boiler’s maximum output. Th...

  • Page 24: Thermostatic Radiator Valves

    Supplied by www.Heating spares.Co tel. 0161 620 6677 23 thermostatic radiator valves if a room control unit is installed, at least one of the radiators in the reference room must be without a thermostatic valve. For better temperature comfort, we recom- mend to leave all radiators in the referen- ce...

  • Page 25: System

    Supplied by www.Heating spares.Co tel. 0161 620 6677 24 operating pressure in the heating system the heating system (measured on the boiler) must be filled at least to the hyd- raulic pressure of 1 bar (corresponds to a 10 m hydrostatic water column). We re- commend that you maintain the pressure wit...

  • Page 26: Hew Safety Valve

    Supplied by www.Heating spares.Co tel. 0161 620 6677 25 hew safety valve the system safety valve is situated at the bottom of the boiler on the left side of the hydraulic group (fig. 13). When the maxi- mum pressure in the system is exceeded, water or steam can be discharged through the safety valve...

  • Page 27: Draining Hew

    Supplied by www.Heating spares.Co tel. 0161 620 6677 26 from switching on the main switch the boi- ler will be shut down, the boiler display will show f0, flashing led at symbols and . • press once the mode button to display the approximate value of the heating wa- ter in the system (see the pressure...

  • Page 28: Air Supply/combustion Gases

    Supplied by www.Heating spares.Co tel. 0161 620 6677 27 in the case of model ktz combustion ga- ses must be removed and fresh air sup- plied through special dual tubing. Horizontal tubing sections must have a gradient allowing water condensate to run towards the boiler or to special condens- ate rem...

  • Page 29

    Supplied by www.Heating spares.Co tel. 0161 620 6677 28 example of a vertical route of dual tubing – design c32 (according to en 483) is il- lustrated in fig. 18. Method c 42 – connection to common dual chimneys. Dual tubing from each boiler (individual routes) may be terminated in a common chimney;...

  • Page 30: Vernment Decree No. 92/1996

    Supplied by www.Heating spares.Co tel. 0161 620 6677 29 (or special chimney or shaft) - if the tubing does not contain such pieces, it must be supplemented (combined with) compo- nents from other tubes (e.G. Tubing from the manufacturer). Spôsob c 82 – tubing with the air supply part terminated in f...

  • Page 31: Very Important!

    Supplied by www.Heating spares.Co tel. 0161 620 6677 30 fig. 22b fig. 22a fig. 22a - dual outlet in horizontal con- figuration on a straight external wall dual outlet in vertical configuration minimum distances with dual outlet in ver- tical configuration on a straight external wall should be: a = 0.5...

  • Page 32: Safety Measures

    Supplied by www.Heating spares.Co tel. 0161 620 6677 31 safety measures the distance of flammable materials from the flue section of the separated tubing must be such that the surface tempera- ture of these materials does not exceed 80 °c. Flue tubing termination must not be located in areas: • with e...

  • Page 33

    Supplied by www.Heating spares.Co tel. 0161 620 6677 32 the terminal box for wiring a room control unit, which is factory-fitted with a jumper, is situated on the back of the boiler control panel. The terminal box is accessible after removing the outside cover and tilting the control panel (fig. 23)....

  • Page 34: Electrical Dia

    Supplied by www.Heating spares.Co tel. 0161 620 6677 33 electrical dia gram of pr otherm tig er 24 (12) k oz boiler fig. 24.

  • Page 35: Electrical Dia

    Supplied by www.Heating spares.Co tel. 0161 620 6677 34 electrical dia gram of pr otherm tig er 24 (12) k oz boiler fig. 25.

  • Page 36

    Supplied by www.Heating spares.Co tel. 0161 620 6677 35.