PS Audio P3 Owner's Reference Manual - page 12
4826 Sterling Drive, Boulder, CO 80301
PH: 720.406.8946 service@psaudio.com www.psaudio.com
10
®
Operation Guide
©2012 PS Audio International Inc. All rights reserved.
Owner’s Reference
P3
You may label each outlet to match the device connected. Type the desired label in the text field
above each outlet and click the ‘Submit Changes’ icon.
By clicking on the Power Switch you may turn the power to the selected zone on or off.
You may change the way each outlet interacts with the Master Power button by altering the switch
mode as follows.
The outlet remains on regardless of the state of the Power Button.
The outlet will follow the state of the Power Button.
The outlet will follow the state of the Power Button after a 3 second delay.
The outlet will follow the state of the Power Button after a programmed delay. Note: The Program
Delay can only be altered through the web based interfaces, the default is 3 seconds.
The outlet is ALWAYS ON, but may be rebooted through the web
Interface.
The outlet is ALWAYS ON, may be rebooted from the web interface, and automatically reboots when
no web connection is detected for 10 minutes. When Auto Reboot is selected one may use the on
and off delays to sequence power of all Auto Reboot outlets.
** Important: Changes made in the configuration tab must be
confirmed by clicking on the Submit Changes button at the
top of the page. **
One of the most distinguishing features of GlobalNet and the P3 is its ability to alert you to possible
problems with your system. The Email Alerts tab will allow you to configure email alerts. Configuring
email alerts is easy, just check the boxes next to the alerts you wish to receive, enter the email
address or addresses you wish them to be sent to and click SAVE CHANGES.
The Performance tab will allow you to monitor the incoming power conditions and wattage
consumption over time of your P3.
The Wattage tab allows you to configure high and low wattage tolerances, and actions based off of
exceeded tolerances.
The networking tab allows some controls of the network settings for the Perfect Wave P3.
Offers the ability to monitor various IP addressed devices on the local network then Reboot devices
based off of a failed response. This feature is sometime referred to as the network watchdog. The
feature can even alert you via email alerts to reboot events or failed responses on the local network.
Enter the IP address of the device that you would like the P3 to monitor.
Performance
Wattage
Network
IP Ping
IP Address
Outlet Labeling
Switch Mode
Switched
Program Delay
Auto Reboot
Alerts
Reboot
Delayed
Power Toggle
Always On