QMS CF 2215 User Manual - page 30
Using the
Emulation
QMS MAGNUM Emulation User's Guide
2-16
Control Char
Sets the default control character.
^
PY
^
- Line TRM
Stipulates the number of characters the controller ignores following
the ^PY^- command, which enables MAGNUM conversion.
Default
Disable
Notes
To enable Ignore mode on MAGNUM emulation start-up,
set both this option and the Administration/Emulations/
MAGNUM/Code V Setup/Ignore Mode/Conversion option
to On. See the
Code V Version II Programming Language
Manual for more information on the ^X and ^A commands
that toggle the Ignore Mode.
Menu
Administration/Emulations/MAGNUM/Code V Setup/Control Char
Choices 00 to 99
Default
94
Notes
QMS recommends that the control character be a non-
printable character. This includes alphanumeric characters,
characters between Hex 00 and Hex 11F (inclusive),
lowercase characters, and the character N (Hex 4E).
Remember that the control character may also be changed
by using Code V programming language commands. See
the
Code V Version II Programming Language Manual for
more information.
Menu
Administration/Emulations/MAGNUM/Code V Setup/^PY^- Line TRM
Choices One Character—Forces a line feed and starts printing on
the second line of the page. Since the ^PY^- must be
on the first line of the program and must be the only
command on that line, a carriage return and line feed
must follow it. The line feed forces printing to begin on
the second line.
Two Character—Ignores both carriage return and line feed
and starts printing on the first printable line of the page.