    1 7045-909 october 22, 2013 notice: do not discard this manual 41-i acc wood insert automatic combustion control (acc) model(s): 41i-acc owner’s manual operation & care installer: leave this manual with party responsible for use and operation. Owner: retain this manual for future reference. Contact ...

  • Page 2: Caution:

    2 7045-909 october 22, 2013 41i-acc a. Congratulations hearth&hometechnologieswelcomesyoutoourtradition of excellence! In choosing a quadra-fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ...

  • Page 3

    October 22, 2013 7045-909 3 41i-acc table of contents safety alert key: • danger!Indicates a hazardous situation which, if not avoided willresultindeathorseriousinjury. • warning! Indicates a hazardous situation which, if not avoided mayresultindeathorseriousinjury. • caution!Indicates a hazardous s...

  • Page 4

    4 7045-909 october 22, 2013 41i-acc page 54 7022-122 january 19, 2011 r castile pellet insert 4021-645c 12-29-10 page 1 of 2 hearth & home technologies inc. Limited lifetime warranty hearth & home technologies inc., on behalf of its hearth brands (”hht”), extends the following warranty for hht gas, ...

  • Page 5

    October 22, 2013 7045-909 5 41i-acc r january 19, 2011 7022-122 page 55 castile pellet insert 4021-645c 12-29-10 page 2 of 2 warranty conditions: ...

  • Page 6

    6 7045-909 october 22, 2013 41i-acc d. Quick start guide note: thesearegenericdrawingsandmaynotrepresentyourspecificmodel. The stove is ready for normal operation. 2 3 6 items needed for first fire: load wood add newspaper add more wood 4 add kindling light the paper 7 reduce air control set to desi...

  • Page 7

    October 22, 2013 7045-909 7 41i-acc model: 4100-i (acc) insert laboratory: intertek report no: 100428837prt-001 type: solidfueltype,listedroomheater standard: ul1482 and ulc s628-93 and (um)84-hud,mobilehome approved. Epacertified: 4.3 grams per hour efficiency: up to 80.2% epa btu output: 11,700 to...

  • Page 8: User Guide

    8 7045-909 october 22, 2013 41i-acc surround & trim set burn rate control door handle blower control and power cord blower location start-up air control user guide 2 operating instructions warning! Do not operate appliance before reading and understanding operating instructions. Failuretooperateappl...

  • Page 9: Warning

    October 22, 2013 7045-909 9 41i-acc b. Fire safety toprovidereasonablefiresafety,thefollowingshouldbe given serious consideration: 1. Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away from the heating appliance and close to the sleeping...

  • Page 10

    10 7045-909 october 22, 2013 41i-acc f. Burning process in recent years there has been an increasing concern about air quality. Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve the situation, we at quadra-fire have developed cleaner-...

  • Page 11

    October 22, 2013 7045-909 11 41i-acc figure 11.1 start-up and burn rate air cont rols burn rate control start up air control figure 11.2 manual timer over-ride 1 2 g. Automatic combustion control (acc) typically,whenyoubuildafire,youopentheaircontrolsfully andmonitorthefiretopreventitfromgoingintoan...

  • Page 12

    12 7045-909 october 22, 2013 41i-acc figure 12.1 air control high low 3. Burn rate air control • the air supply enters at the upper front of the firebox, near the top of the glass door. • this preheated air supplies the necessary fresh oxygen to mix with the unburned gases, helping to create the sec...

  • Page 13: Correct Position

    October 22, 2013 7045-909 13 41i-acc correct position incorrect positions j.Correctbaffle&blanketplacement ceramicblanketandbaffleboardarenot incontactwiththebackofthefirebox. Ceramic blanket is not in contact with the backofthefireboxandnotevenwiththe baffleboardinthefront. Ceramic blanket is bunch...

  • Page 14

    14 7045-909 october 22, 2013 41i-acc k. Building a fire beforelightingyourfirstfireintheappliance: 1. Confirm the baffle and ceramic blanket are correctly positioned. They should be even with the front tube and resting on all tubes. See page 13. 2. Remove all labels from glass. Therearemanywaystobui...

  • Page 15

    October 22, 2013 7045-909 15 41i-acc l. Wood fuel soft woods hard woods •douglasfir •oak •pine •maple •spruce •apple •cedar •birch •poplar •aspen •alder moisture themajorityoftheproblemsapplianceownersexperience are caused by trying to burn wet, unseasoned wood. • wet, unseasoned wood requires energ...

  • Page 16

    16 7045-909 october 22, 2013 41i-acc auto: fan will turn on/off automatically and is controlled by the internal snap disc manual: over-rides the internal snap disc m. Operating the blower control box with snap disc 1. The blower will turn on/off automatically when set to auto. Figure 16.1. 2. When s...

  • Page 17

    October 22, 2013 7045-909 17 41i-acc q. Opacity (smoke) opacity is the measure of how cleanly your appliance is burning. Opacity is measured in percent: • 100%opacityiswhenanobjectistotallyobscuredby the smoke column from a chimney, and • 0%opacitymeansthatnosmokecolumncanbeseen. As you become famil...

  • Page 18

    18 7045-909 october 22, 2013 41i-acc whenproperlymaintained,yourfireplacewillgiveyoumanyyears of trouble-free service. Contact your dealer to answer questions regarding proper operation, troubleshooting and service for your appliance. Visit www.Quadrafire.Com tofindadealer.Werecom- mendannualservice...

  • Page 19

    October 22, 2013 7045-909 19 41i-acc e. Glass cleaning • frequency:as desired • by:homeowner • clean glass with a non-abrasive glass cleaner. Abrasive cleaners may scratch and cause glass to crack. • if the deposits on the glass are not very heavy, normal glass cleaners work well. Heavier deposits m...

  • Page 20

    20 7045-909 october 22, 2013 41i-acc baffle&blanket optional blower chimney system firebrick&ashremoval door&glassassemblies doorhandle frequency monthly or after every cord of wood baffleandblanketplacementiscriticalto heatoutput,efficiencyandoveralllifeof theunit.Makesurethebaffleispushedall ofthe...

  • Page 21

    October 22, 2013 7045-909 21 41i-acc with proper installation, operation, and maintenance your wood stove will provide years of trouble-free service. If you do experienceaproblem,thistroubleshootingguidewillassistyouoraqualifiedservicepersoninthediagnosisofaproblem and the corrective action to be ta...

  • Page 22

    22 7045-909 october 22, 2013 41i-acc a. Glass replacement - door assembly (replace with 5mm ceramic glass only) 1. Ensurethatthefireisoutandtheapplianceiscoolto the touch. 2. Protect a table or counter top with padding or towels. Protectyourhandsandwearglovestopreventinjury. 3. Remove the door with ...

  • Page 23

    October 22, 2013 7045-909 23 41i-acc c. Blower replacement 1. Removethe2screwsfromtheblowerhousingassem- bly using a 5/32 allen wrench. Figure 23.1. 2. Disconnect the wires from the blower. 3. Remove the 2 screws from the hold down bracket and pull the blower and bracket forward. 4. Remove the blowe...

  • Page 24

    24 7045-909 october 22, 2013 41i-acc figure 24.3 - door handle for arched door d.Baffleremoval 1.Removeallashfromthefirebox,andextinguishallhot embers before disposal into a metal container. 2. Thebaffleboardhas2pieces.Withtheceramicblanket stillinplace,slideonebafflepieceoverthetopofother one but s...

  • Page 25

    October 22, 2013 7045-909 25 41i-acc g. Tube channel assembly replacement removing tube channel assembly 1. Remove the right side bricks (3 pieces). 2.Removethebaffleprotectionchannelbyrollingforward andoutofthefirebox. 3. Locate the 2 channel nuts and 2 channel bolts inside of chamber and remove. N...

  • Page 26

    26 7045-909 october 22, 2013 41i-acc 6 reference materials date of service performed by description of service a. Service & maintenance log.

  • Page 27: 41I-Acc-Bk

    October 22, 2013 7045-909 27 41i-acc b. Service parts & accessories service parts beginning manufacturing date: sept 2011 ending manufacturing date: active 41i-acc-bk r wood insert part number list on following page. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 19 20 21 17 22 23 24 25 04/13.

  • Page 28: 41I-Acc-Bk

    28 7045-909 october 22, 2013 41i-acc service parts beginning manufacturing date: sept 2011 ending manufacturing date: active 41i-acc-bk r important:thisisdatedinformation.Whenrequestingserviceorreplacement parts for your appliance please provide model number and serial number. All parts listed in th...

  • Page 29: 41I-Acc-Bk

    October 22, 2013 7045-909 29 41i-acc service parts beginning manufacturing date: sept 2011 ending manufacturing date: active 41i-acc-bk r important:thisisdatedinformation.Whenrequestingserviceorreplacement parts for your appliance please provide model number and serial number. All parts listed in th...

  • Page 30: 41I-Acc-Bk

    30 7045-909 october 22, 2013 41i-acc service parts beginning manufacturing date: sept 2011 ending manufacturing date: active 41i-acc-bk r important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts lis...

  • Page 31

    October 22, 2013 7045-909 31 41i-acc.

  • Page 32

    32 7045-909 october 22, 2013 hearth & home technologies 1445 north highway colville, wa 99114 division of hni industries do not discard this manual caution • importantoperatingand maintenance instruc- tionsincluded. • leavethismanualwith partyresponsibleforuse andoperation. • read,understandand foll...