Quadra-Fire 41I-ACC Owner's manual - page 16
16
7045-909
October 22, 2013
41I-ACC
AUTO: Fan will turn ON/OFF
automatically and is controlled
by the internal Snap Disc
MANUAL: Over-rides
the internal Snap Disc
M. Operating the Blower Control Box with
Snap Disc
1. The blower will turn on/off automatically when set to
AUTO.
Figure 16.1.
2. When set to MANUAL, the fan will turn on/off only when
you turn it on or off. This setting over-rides the internal
snap disc.
3. Adjust the speed of the fan by turning the HIGH/LOW
knob to the desired setting.
N. Blower Operating Instructions
1.
Initial (cold) startup:
Open both controls fully by rais-
ing the Burn Rate Air Control all the way up until it stops
and push the Start-up Air Control back until it stops.
The
blower tends to cool the appliance. Leave the blower off
until the burn is well established, i.e., 30 minutes.
2
. High Burn Setting: Both controls are open. Burn Rate
Air Control is pulled up and the Start-up Air Control is fully
pushed in. Blower may remain on.
3.
Medium High Burn Setting*: Burn Rate Air Control
is closed then opened to 1 inch (pull up )to fully open.
Blower may remain on.
4.
Medium Low Burn Setting*: Burn Rate Air Control is
closed then opened to 1/4 inch to 1/2 inch. Leave the
blower off until the burn is well established, i.e., 30 min-
utes.
5.
Low Burn Setting*: Burn Rate Air Control is closed.
Leave the blower off until the burn is well established, i.e.,
30 minutes.
*NOTE: For burn settings 3 to 5 the Start-up Air Control
needs to be pushed in (Open) then pulled forward to acti-
vate the Automatic Combustion Control (ACC).
NOTE: Formaximumefficiencyandlowestemissions,
when operating the blower in either the automatic or
manual setting for the low and medium low burn settings
leave the blower off until the burn is well established, i.e.,
30 minutes.
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostaton,thenadjustingbacktowards“OFF”asfaras
possible without turning the blower off. For a low blower
speed, turn the control knob clockwise as far as possible
Figure 16.1