Quadra-Fire 41I-ACC Owner's manual - page 22
22
7045-909
October 22, 2013
41I-ACC
A. Glass Replacement - Door Assembly
(Replace with 5mm ceramic glass only)
1. Ensurethatthefireisoutandtheapplianceiscoolto
the touch.
2. Protect a table or counter top with padding or towels.
Protectyourhandsandwearglovestopreventinjury.
3. Remove the door with the broken glass by lifting the door
up and off of the hinges.
4. Lay door face down on a table or counter making sure
thehandlehangsovertheedgesothedoorlaysflat,on
a soft surface.
5. Remove the screws from each glass retainer and remove
theglass.(Ifscrewsaredifficulttoremove,soakwith
penetratingoilfirst).
6. Center the glass with edges evenly overlapping the
opening in the door, (i.e. same space top and bottom,
left and right sides).
7. Replace the glass retainers. Be careful not to cross
thread the screws.
8. Tighten each retainer just a few turns until each is
secured. Check again for centering of glass in door
frame. Continue to tighten each retainer alternately, a
few turns at a time, until the glass is secure. DO NOT
OVERTIGHTEN - can cause glass to break.
9. Replace the door on the appliance.
Quadra-Fire appliances are equipped with ceramic super
heat-resistant glass, which can only be broken by impact
or misuse.
WARNING! Risk of Fire or Injury!
Useonlyglassthatisspecifiedinthemanual,DONOT
replacewithanyothermaterial.Glassbreakagewilloccur.
CAUTION!
Handleglasswithcare.
• Inspectthegaskettoensureitisundamaged.
• DoNOTstrike,slamorscratchglass.
• DoNOToperateappliancewithglass&doorassembly
removed.
• DoNOToperatewithglasscracked,brokenor
scratched.
Shock Risk.
• DoNOTremovegroundingprongfromplug.
• Plugdirectlyintoproperlygrounded3prong
receptacle.
• Routecordawayfromappliance.
• Do NOT route cord under or in front of appliance.
CAUTION
5
Service Parts Replacement
Figure 22.1
B. Snap Disc Replacement
1. The snap disc bracket assembly is located on top of the
blower assembly towards the side.
Figure 22.1.
2. Remove the 2 allen head bolts using a 5/32 Allen wrench
from the blower housing and pull the housing towards you.
3. Using a Phillips head screw driver, remove the 2 screws
from the Blower Assembly as shown and slide assembly
out.
4. Using a Phillips head screw driver, remove the 2 screws
from the snap disc and then remove the snap disc from
the spade connectors. Replace with new snap disc and
re-connect to spade connectors.
5. Re- install in reverse order
Blower Housing Assembly
Blower Assembly
Snap Disc