    1 7019-229c june 25, 2015 notice: do not discard this manual santa fe pellet insert stove model(s): santafei-mbk o-t l tested and listed by portland oregon usa omni-test laboratories, inc. C us owner’s manual operation & care installer: leave this manual with party responsible for use and operation....

  • Page 2

    2 7019-229c june 25, 2015 santa fe pellet insert b. Sample of serial number / safety label location: on chain behind right access panel & behind left access panel sample: serial number label location: behind left access panel. Sample: clearance to combustibles label location: on chain behind right a...

  • Page 3

    June 25, 2015 7019-229c 3 santa fe pellet insert table of contents safety alert key: • danger!Indicates a hazardous situation which, if not avoided will result in death or serious injury. • warning! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • caut...

  • Page 4

    4 7019-229c june 25, 2015 santa fe pellet insert hearth & home technologies inc. Limited lifetime warranty hearth & home technologies inc., on behalf of its hearth brands (”hht”), extends the following warranty for hht gas, wood, pellet, coal and electric hearth appliances that are purchased from an...

  • Page 6

    6 7019-229c june 25, 2015 santa fe pellet insert model santa fe pellet insert laboratory omni test laboratories, inc. Report no. 061-s-77d-6.2 type solid fuel room heater/pellet fuel burning type insert standard astm e1509-2004, ulc s628-93 and ulc/ord-c1482-m1990 room heater pellet fuel burning typ...

  • Page 7: User Guide

    June 25, 2015 7019-229c 7 santa fe pellet insert user guide 2 operating instructions a. Fire safety to provide reasonable fi re safety, the following should be given serious consideration: • install at least one smoke detector and co monitor on each fl oor of your home. • locate detectors away from ...

  • Page 8

    8 7019-229c june 25, 2015 santa fe pellet insert e. General operating information 1. Thermostat calls for heat the appliance is like most modern furnaces; when the thermostat calls for heat, your appliance willautomatically light and deliver heat. When the room is up to temperature and the thermosta...

  • Page 9

    June 25, 2015 7019-229c 9 santa fe pellet insert warning fire risk. • high ask fuels, or lack of maintenance, can cause the fi repot to fi ll with ash and clinker. If the fi repot fi lls to the top, immediately shut down the appliance and clean. • failure to do so could result in smoking, sooting an...

  • Page 10

    10 7019-229c june 25, 2015 santa fe pellet insert odors and vapors released during initial operation. • curing of high temperature paint. • open windows for air circulation. Odors may be irritating to sensitive individuals. Caution m. Frequently asked questions issues solutions 1. Metallic noise 1. ...

  • Page 11

    June 25, 2015 7019-229c 11 santa fe pellet insert 3 maintenance and service when properly maintained, your fi replace will give you many years of trouble-free service. Contact your dealer to answer question regarding proper operation, troubleshoot- ing and service for your appliance. Visit www.Quadr...

  • Page 12

    12 7019-229c june 25, 2015 santa fe pellet insert time you clean the fi rebox. Remember to place the ash and debris into a metal or non-combustible container. E. The 2 cleaning slide plates must be fully closed when cleaning is complete. 4. Cleaning ash drawer • frequency: weekly or every 5 bags of ...

  • Page 13

    June 25, 2015 7019-229c 13 santa fe pellet insert figure 13.1 cleaning rods 10 heat exchanger tubes warning heat exchanger cleaning rods may be warm to the touch. For safety purposes wear gloves. Do not pull heat exchanger cleaning rods while appliance is operating. Push cleaning rods in when done, ...

  • Page 14

    14 7019-229c june 25, 2015 santa fe pellet insert 11. Cleaning exhaust blower - requires no lubrication • frequency: yearly or as needed • by: quality service technician/homeowner a. Remove left & right brick. The exhaust blower is behind the right brick. Vacuum this area thoroughly. See page 17 for...

  • Page 15

    June 25, 2015 7019-229c 15 santa fe pellet insert d. Thermostat battery installation and replacement note: 2 aa batteries are included with the thermostat and must be installed before the appliance can be oper- ated. Install fresh batteries immediately when the replace battery warning begins fl ashi...

  • Page 16

    16 7019-229c june 25, 2015 santa fe pellet insert with proper installation, operation, and maintenance your appliance will provide years of trouble-free service. If you do experience a prob- lem, this troubleshooting guide will assist a qualifi ed service person in the diagnosis of a problem and the...

  • Page 17

    June 25, 2015 7019-229c 17 santa fe pellet insert 5 service parts replacement 2. Convection blower replacement a. The blower is located at the bottom rear of the insert. If an outside air kit is also installed, you will fi rst need to remove the outside air fl ange by removing the 2 screws using a p...

  • Page 18

    18 7019-229c june 25, 2015 santa fe pellet insert brick is flush against back wall notches exposed c. Re-installing baffl e & brick set 1. Place right brick in behind the right bracket, and then slide to the left so the tabs are behind the center brick. Figure 18.4. 2. The brick will be fl ush again...

  • Page 19

    June 25, 2015 7019-229c 19 santa fe pellet insert figure 19.2 hook on left side tab on right side figure 19.3 figure 19.4 figure 19.5 lift brick, pull forward at an angle and drop down into notches figure 19.1 re-installing baffl e & brick set (cont’d).

  • Page 20

    20 7019-229c june 25, 2015 santa fe pellet insert d. Igniter replacement a. Shut down the appliance by turning down the thermostat and let the appliance completely cool down. After the appliance has cooled down, unplug it and remove the ash drawer. B. The wire leads to the igniter are connected to t...

  • Page 21

    June 25, 2015 7019-229c 21 santa fe pellet insert 6 reference materials 2. Convection blower the convection blower is mounted at the bottom rear of the appliance. There are 2 impellers, one on each side of the motor. The convection blower pushes heated air through the heat exchange system into the r...

  • Page 22

    22 7019-229c june 25, 2015 santa fe pellet insert 17. Snap disc #1 (convection blower) 110°f snap disc #1 is located on the right side of the fi rebox. There are 2 purple wires connected to it. This snap disc turns the convection blower on and off as needed. Power is always present at snap disc #1. ...

  • Page 23

    June 25, 2015 7019-229c 23 santa fe pellet insert feed motor snap disc #1 exhaust blower convection blower heat output switch reset button leveling bolt outside air intake flue connector vacuum switch junction box control box junction box, front exhaust collar power cord recpticle terminal block cen...

  • Page 24: Santafei-Mbk

    24 7019-229c june 25, 2015 santa fe pellet insert service parts r santafei-mbk beginning manufacturing date: dec. 2009 ending manufacturing date: active pellet insert part number list on following page. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 0...

  • Page 25: Santafei-Mbk

    June 25, 2015 7019-229c 25 santa fe pellet insert service parts r santafei-mbk beginning manufacturing date: dec. 2009 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to c...

  • Page 26: Santafei-Mbk

    26 7019-229c june 25, 2015 santa fe pellet insert service parts r santafei-mbk beginning manufacturing date: dec. 2009 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to c...

  • Page 27: Santafei-Mbk

    June 25, 2015 7019-229c 27 santa fe pellet insert service parts r santafei-mbk beginning manufacturing date: dec. 2009 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to c...

  • Page 28: Santafei-Mbk

    28 7019-229c june 25, 2015 santa fe pellet insert service parts r santafei-mbk beginning manufacturing date: dec. 2009 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell directly to c...

  • Page 29

    June 25, 2015 7019-229c 29 santa fe pellet insert.

  • Page 30

    30 7019-229c june 25, 2015 santa fe pellet insert.

  • Page 31

    June 25, 2015 7019-229c 31 santa fe pellet insert.

  • Page 32

    32 7019-229c june 25, 2015 do not discard this manual caution • important operating and maintenance instruc- tions included. • leave this manual with party responsible for use and operation. • read, understand and follow these instruc- tions for safe installa- tion and operation. Do not discard cont...