G. Error Codes
Ifasystemerroroccursthatforcesthesystemtostopop-
eratinganerrorscreenappears.Dependingupontheerror
type, up to three retry attempts are allowed after which a
serviceprofessionalisrequired.
Press the ERROR LIST button to display the latest error.
Figure 10.1.
Seepage 11foralistoferrorcodes.
F. Service Information
TheSERVICEINFORMATIONscreendisplayscontactin-
formationforHearth&HomeTechnologiesCustomerSer-
viceLine.Thelocaldealermayhavechangedthisuponor
beforetheinstallationtoindicateadealerhotline.
www.quadrafire.com
to locate your nearest
dealer
DONE
ERROR LIST
Figure 10.2
MANUAL LIGHT PROCEDURE
Press “CONTINUE”
button to start manual
lighting sequence
Current Tem: 72 F
O
CONTINUE
MANUAL LIGHT PROCEDURE
Please wait while
feed charge is loading
into firepot
MANUAL LIGHT PROCEDURE
Open door...
Manually light fuel...
Close door
Figure 10.1
13 Volts
12 Volts
11 Volts
Battery
Below
10 Volts
OperatingonBatteryBack-Up
•
Abatteryiconappearsonyourwallcontroltoletyou
knowyouarenowoperatingonbatterypower.Figure
10.3.
• Thefiremustbemanuallylitastheappliancewillno
longerautomaticallylight.See page 4.
•
Useonlyapprovedfirestartinggeltostartthefire.
• The high burn rate is no longer available on battery
back-up.
• Eachleveldropsdownonelevel,i.ethehighburnbe-
comesmedium-highburnandsoon.
• Ifthebatterychargefallsbelow10voltitcannolonger
sustaintheapplianceoperationandtheappliancewill
shutdown.Youmustdisconnectandreconnectthebat-
terytostartitupagain.
RecommendedBattery
• 12voltdeepcyclebattery,(i.e.,marineorRVtype).
•
A12voltbatterycableisavailablethroughyourlocal
dealer.
Figure 10.3
MAINT BURN
73
Set at: 73
12:30 PM
HEAT OUTPUT
MENU
“Maint Burn” will display when
the thermostat has reached the
set room temperature and will
run on low until it reaches its
auto-clean clycle time.
Battery icon.
Figure 10.4
WallControlDisplay
Thewallcontrolwilldisplaythebatteryiconwhenoperating
inthebatteryback-upmode.Figure 10.4.
H. Battery Back-up System (Optional)
Theappliancehasbeendesignedtooperateonanoptional
batteryback-upsystem.
If you have frequent power outages in your region, hook
theapplianceuptoa12voltbatteryanditwillautomatically
switchtobatterypowerintheeventofapowerfailure.The
12voltpowercordsoldasaseparateaccessorydoesnot
chargethebattery.
RefertotheOwner’sManualforyourapplianceforinstructions
onhowtoattachthecabletoyourappliance.Thefollowing
arethescreensyouwillseewhenusingaback-upbattery.