FIREPLACE INSERT
INSTALLATION
The fireplace insert can be installed after the
mantel has been fully assembled.
WARNING: Make sure the fireplace insert
controls are in the ‘OFF’ position and the unit
is not plugged in.
Step 1: Place the INSERT in the back of the
mantel on the floor. Carefully lift the INSERT
into the mantel until the top stopper is
against to MANTEL.
Step 2: Attach 2 MOUNTING CLIPS (U) onto
the top of insert and lock in place with 2
SHORT KD SCREWS (T). Attach 2 MOUNT-
ING BRACKETS (V) to the bottom of insert
with 2 SHORT KD SCREWS. See Fig. H
fig. H
WALL ANCHOR
SAFETY CABLE
The use of WALL ANCHOR SAFETY CABLE
is highly recommended in order to reduce
the risk of the fireplace being tipped over
accidentally. WARNING: This CABLE may
reduce possible risk of injury if the fireplace
is improperly handled, but is not a substi-
tute for proper adult supervision. Children
should not be left unattended near any
heater.
1. Drill a 5/16” (8mm) hole in the wall. Insert
the PLASTIC WALL ANCHOR into the
hole and gently tap until the flange on the
anchor is against the wall surface.
2. Position the back edge of the mantle
close to the wall.
3. Attach the SAFETY CABLE to the mantle
using the SCREW FOR MANTLE.
4. Use the SCREW FOR WALL to attach the
other end of SAFETY CABLE to the wall.
5. Make sure all screws are tight.
Wall
After reading complete instructions,
confirm all controls on fireplace are in
the OFF position. Plug the fireplace into a
15AMP/120Volt outlet. If the cord does not
reach, you may use an extension cord rated
for a minimum of 1875 WATTS. Once the
fireplace insert has been properly con-
nected to a grounded electrical outlet, it is
ready to operate. Once the fireplace insert
has been properly connected to a grounded
electrical outlet, it is ready to operate.