Quantum QP2125 Instruction Manual - page 11
Rated output ( 100V line )
Power requirement
Power consumption (240V ac )
Standby power consumption
Standby current ( 240V ac )
Full load current ( 240V ac )
4 Ohm output
Input sensitivity
Input gain control
Input connection
Tone controls
Fault sensing
Detection response
Fault contact
Freq. response
S/N ratio
Data connection
Protection
Thermal prot.temp (C)
Fan controls
Dimensions ( WxHxD) mm
Weight (kg)
Technical Specifications
125W 250W 375W 500w
220 - 240V ac 50/60 Hz
300VA 440VA 580VA 720VA
12VA ; 240V ac
0.05A
1.2A 1.83A
2.4A
3A
28V
31.6V 38.7V 44.8V
1v / 10 K Ohm
-40 to 0 dB
XLR balanced ( M/F )
Bass / Treble digital control
Switchable pilot tone ; 20 KHz
15 - 25 seconds
3A dry contact relay ( NO )
70 - 15 KHz @ 1KHz +/-3dB
> 60 @ 1 KHz ; 1V
RS485 : 19.2 kbps
Thermal, short circuit, circuit breaker, input signal
75
Manual / auto with speed control
481 x 88 x 335
12 13 16 18
QP2125 QP2250 QP2375 QP2500
Summary of Features
Digital Setting for various parameters with LCD display
Auto fault sensing ( AFS ) with fault contact
Built in standby amplifier changeover
RS485 interface for monitoring and remote setting
Tone and bass controls
Auto fan speed controls
Thermal, fuse, output short circuit protections