QUATTRO EMS GM380E Operation Manual

Summary of GM380E

  • Page 1

    Powered muscle stimulator (ems) read before using quattro ems model: gm380e (4ch ems) fda 510k operation manual.

  • Page 2

    Table contents general description 1 system components 1 warranty 1 indications and contraindications 1 warnings and precautions 2 about the device 3 the device controls 4 danger 4 attaching the lead wires 4 electrode selection and care 5 tips for skin care 5 connecting the device 5 battery informat...

  • Page 3

    General description electric stimulation has proven its high value as a method of pain therapy and is a great help to the experienced therapist. With some indications, physicians can prescribe a unit to patients for the use at home. This series of device is the combination of two units with dual-cha...

  • Page 4

    Indications for use z relaxation of muscle spasms. Z prevention or retardation of disuse atrophy. Z increasing local blood circulation. Muscle re-education. Z maintaining or increasing range if motion. Z muscle re-education. Z immediate post-surgical stimulation of calf muscle to prevent venous thro...

  • Page 5

    C. Over the menstruating or pregnant uterus; and d. Over areas of the skin which lack normal sensation. Z some patients may experience skin irritation or hypersensitivity due to the electrical stimulation or electrical conductive medium. The irritation can usually be reduced by using an alternate co...

  • Page 6

    The device controls intensity the intensity knobs are located on the front of the unit for the strength adjustment of the stimulation and also function as on/off controls. Mode the mode key is used to select / set the type of treatment utilized. The available stimulation modes for each unit are as i...

  • Page 7

    The lead wires provided with the device insert into the jack sockets located on rear of the unit. Holding the insulated portion of the connector, push the plug end of the wire into one of the jacks. After connecting the wires to the stimulator, attach each wire to an electrode. Lead wires provided w...

  • Page 8

    With your electrodes. Before attaching the electrodes, identify the area in which your physician/practitioner has recommended for electrode placement. 2. Connect lead wires to the electrodes connect the lead wires to the electrodes before applying the electrodes to the skin. Note: be sure all intens...

  • Page 9

    9-volt dc adaptor because the current consumption is large for the device, it is recommended to use the 9v dc adaptor. Plug the dc plug into the dc jack of the unit, and plug the adaptor into your 110v wall outlet. Please be sure you are using the correct polarity of dc plug. Cleaning for your devic...

  • Page 10

    Technical specifications channel: four, isolated between channels pulse amplitude: adjustable 0-100ma peak into 500 Ω load each channel, constant current pulse rate: 1hz-160hz (adjustable), 1hz/step pulse width: 300µs fixed. Software ramp up feature: pulse width ramp up when change mode patient comp...

  • Page 11

    Remark: printed in taiwan op-380e-q01 - 9 -.