6.4 Steam dispensing
1. To avoid liquid backwashing into the boiler, discharge the steam using the valve knob.
2. Put the steam nozzle into the container of liquid to be heated.
3. Turn the steam valve knob. The amount of steam dispensed is proportional to the opening of the valve;
the greater the opening of the valve, the greater the amount of dispensed steam.
4. When you have finished dispensing steam, close the valve, remove the pitcher of liquid and
immediately clean residues of heated liquid off the steam nozzle with a damp cloth and discharge a
small amount of steam into the drain tray.
6.5 Drawing of hot water
1. Place the water container under the dispenser.
2. Use the valve to draw the required amount of water.
3. When you have finished dispensing the water, close the valve.
6.6 Turning off the machine
1. Close the water shutoff valve.
2. Move the two position switch to the off position.
7 - MAINTENANCE
To allow the machine to operate properly, follow the maintenance instructions given below.
7.1 Safety rules
Do not use jets of water on the machine. Disconnect the machine from the electric line by moving the
lever of the double position switch to the off position. We recommend unplugging the unit from the wall.
Close the water shutoff valve before performing maintenance and/or cleaning operations.
If the machine malfunctions, do not attempt to repair by yourself but contact the technical support service
right away. If the power cord is damaged, turn off the machine right away, turn off the water and contact
the technical support service. Do not replace it by yourself. Perform cleaning/maintenance operations with
the machine cooled down, preferably wearing gloves to protect hands.
7.2 Cleaning the machine
Clean the steam nozzle and the hot water dispenser after each use. Clean portafilter and baskets. Clean
cup warmer grid and drain tray grid.
7.3 Scheduled checks
Check the tray located under the drain tray every two weeks. Clean the group gasket and screens weekly
using the brush provided.
7.4 Resetting the thermostat
If the red indicator light indicating operation of the boiler heating element does not light up when the
machine is turned on or goes off during operation, reset the safety thermostat by pressing the button
found under the machine. The button must be pressed using the special hole located under the machine
(Figure 3). If resetting the thermostat does not allow the boiler heating element operation indicator light to
go on and/or the thermostat repeatedly cuts off power to the heating elements, contact the technical
support service. Contact the dealer in your area for technical assistance.
resettable
Hi limit