R.P.S. Corporation MAGNUM series Operator's Manual - Uncrating Machine
UNCRATING MACHINE
Carefully check the crate for any signs of damage
and that the batteries are in the unit. To uncrate
the machine, remove banding from around the
crate. Take off the top and sides and dispose of
properly. Carefully roll the machine off of the base.
Notify the carrier immediately if concealed
damage is discovered. Cylindrical brushhead is
screwed to the pallet via screws located in the
front solution trough
. DO NOT TURN ON MACHINE
UNTIL THESE SCREWS HAVE BEEN REMOVED.
(SEE BELOW)
PAGE 9
MACHINE SETUP
CONNECTING BATTERIES
Your machine is equipped with (2) 12-volt/205 AH, (4)
6-volt/245 AH or (4) 6-volt/325 AH, deep cycle, batteries,
which form a 24 volt system.
(SEE PICTURE BELOW FOR CORRECT CABLE CONNECTIONS.)
1. Turn all switches to the off position and remove key
(if machine is equipped with optional key switch).
2. Turn on main power switch and check the battery
condition meter to ensure correct installation.
Charge batteries if needed.
(SEE BATTERY CHARGING.)
WARNING!
Batteries are a possible environmental hazard.
Consult your battery supplier for safe disposal methods.
NOTE: Orientation of batteries is critical for cables to reach!
2. Loosen the two knobs
"B"
on the squeegee
and slide them into the slots in the squeegee
mounting plate.
(SEE BELOW)
ATTACHING SQUEEGEE
1. Lower the squeegee mounting plate by
rotating the lift lever
"A"
clockwise.
(SEE BELOW)
4.
You may have to adjust the squeegee pitch.
(SEE ADJUSTING SQUEEGEE ON NEXT PAGE.)
*2 BATTERY CABLE CONNECTIONS*
2. Tighten the two knobs, and connect the
vacuum hose
"C"
from the machine to
the squeegee.
(SEE BELOW)
B
B
C
24-Volts
24-Volts
*4 BATTERY CABLE CONNECTIONS*
A