R.P.S. Corporation MAGNUM series Operator's Manual - Page 24
PAGE 24
be charged. The charging cycle progress will be shown by red (3), yellow (4), and green (5) LED
indicators.
At the end of the charge, when the green indicator (5) is on, unplug the cord from the socket
and operate the machine.
PROBLEMS
SOLUTIONS AND CHECKS
The battery charger does not switch on.
Check that the plug is connected to the supply mains
and that the fuse is efficient.
The charging cycle does not start and the
message “bat” is displayed.
Check the connection to the battery and polarity.
The yellow indicator (4) will not light up even
15 hours from the starting of the charging
cycle, and the display shows E03.
Check the battery for possible faulty components.
The message E01 is displayed.
This means that the maximum voltage admissible by
the battery has been exceeded. The charging is
interrupted.
If the battery charger is provided with a safety
thermostat and the message E02 is displayed.
This means that the maximum temperature has been
exceeded. The charging is interrupted.
The message E03 is displayed.
This means that the maximum time for the charging
phase has been exceeded. The charging is interrupted.
The message SCt is displayed.
This means that the total safety timer has interrupted
the charging.
The message Srt is displayed.
This signals a possible internal short circuit.