RAD V-RAD User Manual - page 6
V-RAD USER MANUAL
New World Technologies Inc.
Page • 4
V2014.07.03
1.0 General Information
1.1 System Components
The V-RAD Tool System is shipped from New World Technologies Inc. in a case with the
following parts:
-
V-RAD Tool (Figure 1.1-1)
-
Standard Reaction Arm and Snap Ring (Figure 1.1-2)
-
Calibration Certificate
-
User Manual
Figure 1.1-1: V-RAD Tool
Figure 1.1-2: Standard Reaction Arm
Note: Some distributors may ship additional parts along with the V-RAD Tool System.
1.2 Specifications
1.2.1 Torque Ranges
The following table outlines the torque ranges, in Foot-Pounds and Newton-Meters, of each
V-RAD Tool System:
Imperial
Metric
V-RAD 4
100-400 FtLb
or
V-RAD 6
135-540 Nm
V-RAD 10
400-1000 FtLb
or
V-RAD 14
550-1350 Nm
V-RAD 16
500-1600 FtLb
or
V-RAD 21
675-2170 Nm
V-RAD 23
800-2300 FtLb
or
V-RAD 31
1100-3100 Nm
Table 1.2.1: Torque Ranges
1.2.2 Electrical Specifications
Ensure that all Electrical Specifications are followed when utilizing the V-RAD Tool System.
Units
120V Model
230V Model
Nominal Input Voltage
VAC
120
230
Minimum Input Voltage
VAC
108
185
Maximum Input Voltage
VAC
133
260
Nominal Tool Voltage
VDC
170
325
Minimum Tool Voltage
VDC
153
262
Maximum Tool Voltage
VDC
188
368
Nominal Input Current
ARMS
8.1
4.2
Nominal Input Power
W
900
900
Table 1.2.2: Electrical Specifications
1.2.3 Environmental Specifications
CAUTION!
Only operate the V-RAD Tool System if the following environmental
storage and operation specifications have been met.
Temperature Ranges
̊ C
̊ F
Operating Temperature
-20 – 35
32 – 104
Storage Temperature
-25 – 70
-13 – 158
Humidity
10% to 90% non-condensing
Shock
10G according to DIN IEC 68-2-6/29
Vibration
1G, 10-150Hz according to DIN IEC 68-2-6/29
Required Operating Conditions
-
Non explosive atmosphere
-
Dry location
Table 1.2.3: Environmental Specifications