Radiant DIAGNOCODE SM 20015 Instruction Manual - page 14
P.C.B. SM 20015 –boiler settings
11
D
B
10
20
30
40
A
MANOMETRO
C
Parameter
11
setting: MAXIMUM HEATING OUTPUT SETTING
To check or modify the existing pressure value:
a. Insert a manometer into the gas valve pressure point B (fig.1);
b. Put ON/OFF button
1
in OFF position (
);
c. Push pad
6
and
simultaneously and keep them pressed;
d. Put ON/OFF button
1
in ON position (
) and wait until the display shows
-
;
e. Release pad
6
and
;
f. Keeping service pad
pressed, press pad
6
and select parameter no.
;
g. Release service pad
press and release service pad
;
h. The display
will show the parameter value to be set or modified;
i. Press pad
6
to increase or pad
to decrease gas pressure according to heating system kW (output) requirement as per table 1 (the gas
pressure value will be displayed in the manometer);
j. Once the required pressure has been reached, press and release service pad
, the display ill show value
;
t. Position the ON/OFF button
1
in OFF position (
)
k. Remove the silicon pipe from the pressure point B (fig.1), close tigly the pressure point screw and make sure there are no gas leaks;
l. Put the ON/OF button in ON position (
);
Gas valve VK 4105G
Fig. 1
PL
0
11
11