Radiant P1220 Configuration Manual - page 7
Configuring Radiant POS terminals
7
Configuring the P1515/P1520 POS terminal
Follow these steps to configure a P1515 or P1520 POS terminal for use with
CounterPoint:
1. If you are using any of the following external devices with your P1515 or P1520,
connect them to the following ports:
Device
Radiant Part #
Port
Printer-driven cash drawer
(16” or 18.8”)
P000F024 or
P000F031
DK (on Epson TM-T88)
Epson TM-T88 series receipt printer
(RS232 interface)
P201F019 or
P201F039
Serial 3
2x20 display (POS mount or
pole mount)
P703F000 or
P703F001
Serial 4
Serial modem
N/A
USB (with USB to serial adapter)
NOTE: If you are using a serial modem with your P1515 or P1520, follow the instructions
included with your USB to serial adapter to connect the modem to an available
USB port.
2. Browse to your top-level directory (e.g.,
C:\SYN) and double-click the SYNRUN.SYN file
to open it in Notepad or another text editor.
3. Add the following lines to
SYNRUN.SYN:
CPSIO3=C
SYNCOM3=98n1
4. If you are not running CounterPoint over Terminal Services, add the following line to
SYNRUN.SYN:
CPSIO4=W
5. Save the modified
SYNRUN.SYN file, and then close your text editor.
6. Copy
the
CP1550Mode.bat and OPOSim.exe files from your top-level directory to the
Windows
Startup directory for all users (i.e., C:\Documents and Settings\All Users\Start
Menu\Programs\Startup).
7. Select
Start / Settings / Printers and Faxes, right-click the Epson TM-T88 - Serial printer, and
then click
Properties.
8. Click
the
Ports tab, select an unused Serial Port (e.g., COM6), and then click OK.
NOTE: Alternatively, you can delete the Epson TM-T88 - Serial printer, instead of assigning
it to an unused port.
9. Start CounterPoint and log in to your company database.
10. Select
File Utilities / Special / System / Update pre-defined data.
11. Select
Yes from the Are you sure you want to do this ? prompt, and then press Enter to
load the pre-defined device codes for Radiant POS terminals.
12. When the pre-defined data is updated, press
ESC to return to the main menu.
13. Select
Setup / Point of Sale / Registers, specify a Register number for your POS terminal,
and then complete the remaining fields on the first
Registers screen.