Radionics K6100 User Manual - K6100-Cnc
K6100-CNC
Terminology
K6100-CNC User Guide
© 2001 Radionics
Page 5
17317 Ver 1.2/48569B
keyholder being added - this would require the keycode and access information to be sent to the door
controllers.
2.2 Notat ion
In the remainder of this document, the following is used to describe parts of the message:
Site Numbers
Ssss
Site Number,
sss
=001-128
- these are allocated automatically by Readykey for Windows and the CNC as sites are added to the system
during installation.
Note: On multi-division Readykey for Windows systems you may have sites from different divisions communicating
through a single CNC as described above. The CNC display does not show the division information.
The Readykey Engine will display information about the relationships between Site Names and Numbers. To
view this information, double-click on the Readykey Engine icon in Readykey for Windows. For each site,
information will be displayed in the form:
MASTER
Door Controllers
D/Ccc
Door Controller Number,
cc
=01-32
The door controllers on each site will have a unique number, or address. These are allocated by the installer
during commissioning of the system.
Normally the first door controller will be address 1. The maximum address on each site will vary, dependent
on how the site communicates to the CNC.
Doors
Dddd
Door Number,
ddd
=001-128
Doors are numbered consecutively on each site. Each door controller may have a maximum of 4 doors.
Door 001 on a site will correspond to door 1 on door controller 1, Door 004 to door 4 on door controller 1,
Door 005 to door 1 on door controller 2, etc. There may be gaps in the numbering if, for example a not all the
possible readers are installed on a particular door controller.
Zones
Zzzzz
Zone Number,
zzzz
=0001-1024
If your system includes Alarm Modules or Alarm Event Managers, then each of these has eight ‘zones’ which
can be used to monitor additional devices. Each door controller may have up to four Alarm Modules or Alarm
Event Managers connected.
Zone 0001 corresponds to zone 1, door 1, door controller 1; Zone 0008 to zone 8, door 1, door controller 1;
Zone 0009 to zone 1, door 2, door controller 1, and so on.
Personnel
IDiiiii
Personnel ID Number,
iiiii
=00001-18000
If your system includes Readykey PIN Readers, then users will need to enter a 4-digit PIN in addition to
using their key/card to gain access through those doors. By adding 1 to the last digit of their PIN, it is
possible for a keyholder to indicate that they are gaining access ‘under duress’. In this case, the ID number
of the keyholder will be indicated. The ID number of keyholders can be found within the Readykey for
Windows Personnel application.
Note: You should ask your installer to provide you with a list of ‘numbers’ for each site, door controller, door and zone
on your system.
The Personnel ID number is displayed for each keyholder in the Readykey for Windows Personnel
application as ‘Record Number’.