Decoder Wiring Procedure - Secondary Path
Connect the two (2) white decoder wires to the
1.
two (2) solenoid coils of the valve-in-head rotor or
remote control valve
Record the decoder address and following the
2.
instructions in the PAR+ES Operation Manual, add
the decoder address to the appropriate station at
the controller
Connect the two blue decoder wires to the wire
3.
path from the controller, one to the red wire and
the other to the black wire
Field Surge Protection for Decoders
LSP-1 surge arrestors are required for surge protection
of decoders and solenoids The LSP-1 surge arrestors
consist of several surge arrestor devices potted in a
cylindrical yellow plastic case The LSP-1 has two blue
wires and two green wires
Install LSP-1s in the following locations:
Install LSP-1s so that there is no more than eight
z
z
decoders between two LSP-1s or so that there is
no more than 500 feet between LSPs, which ever
is less
Install LSP-1s at the last decoder in a dead end of
z
z
a wire path
Connect the two blue wires to the primary path
1.
wire, one to the black and one to the red wire
Connect the green wire that has the closed eye
2.
spade securely to the core tube of the solenoid
on the valve-in-head rotor or to a remote control
valve by using a stainless steel nut threaded onto
the core tube
Connect the green wire to a ground rod on a
3.
grounding grid using a brass clamp
NOTE:
!
A resistance of 50 ohms or less is
required for the LSP-1 surge arrestor to be
effective
If the decoder is not located next to the solenoid,
4.
install the LSP-1 near the decoder and connect
both green wires to the grounding grid using
separate brass clamps
PAR+ES Installation Manual