Rain Bird PAR+ES Installation Manual - page 9
Install MAXI 2-Wire Interface Board
NOTE:
!
Follow this procedure only for 2-wire
installations
The Maxi 2-wire board mounts under the control
module (face panel) of the basic PAR+ES controller
Remove the four screws from the face panel bezel
1.
(not the interior face panel screws) and lift out the
control module
Use four #4-40 machine screws to attach the
2.
MAXI 2-Wire module to the bottom of the control
module, as shown in Figure 7
Cable Connections
Connect the 10-pin ribbon cable from the connector
on the left end of the MAXI 2-Wire board to the 10-pin
connector on the left end of the Power Interconnect
Module
2-Wire Path Connections
On the lower front of the controller is a 4-terminal
connection block (see Figure 8)
Connect the HOT (red) wire of the 2-wire
1.
communication path to terminal #4 (lower right
terminal)
Connect the COM (black) wire of the 2-Wire
2.
communication path to terminal #2
Connect the HOT (red) wire of the 2-Wire
3.
communication path going to the next controller
to terminal #3
Connect the COM (black) wire of the 2-Wire
4.
communication path going to the next controller
to terminal #1 (bottom left terminal)
NOTE:
!
If sharing only one MSP-1 among a
cluster of controllers, then splice the black
and red wires on the EQUIP side of the
MSP-1 Connect one set of wires to the green
plug that connects to the 2-wire interface
board Connect the other set of wires to the
4-terminal connecting block of the second
controller
PAR+ES Installation Manual
7
635778 Rev B (PAR+ES installation manual (1of2 ENG)) source.indd 7